Bosch IRIS-Net User Manual page 477

Table of Contents

Advertisement

IRIS-Net
Commands for Matrix Mixer
/
/DSP
/
PARA
MATRI
M
X_x
Bosch Security Systems B.V.
/
XOVER.HIPAS
S.FREQ
/
XOVER.HIPAS
S.TYPE
/CONNECTCROSSPOINT /
/GAINCROSSPOINT
/GAININ
/VALUE
R / W
20...2000
0
/VALUE
R / W
0...17
Read
Write
Values Description
R / W
0, 1
IDX1...IDX
c
/
R / W
-80...0 Gain of crosspoint.
IDX1...IDX
c
/
R / W
-80...0 Gain of inputs 1 to n of
IDX1...IDX
n
User Manual
DIGITAL MATRIX | en
Frequency of hipass.
Type of hipass.
0 = Off, 1 = 6dB-
Butter-
worth, 2 = 12dB/Q0.5,
3
= 12dB/Q0.6, 4 =
12dB/ Q0.7, 5 = 12dB/
Q0.8, 6
= 12dB/Q1.0, 7 =
12dB/ Q1.2, 8 = 12dB/
Q1.5, 9
= 12dB/Q2.0, 10 =
12dB-Bessel, 11 =
12dB-Butterworth, 12
=
12dB-Linkwitz, 13 =
18dB-Bessel, 14 =
18dB-Butterworth, 15
=
24dB-Bessel, 16 =
24dB-Butterworth, 17
= 24dB-Linkwitz
Connection of crosspoint.
Crosspoints are
numbered column by
column from top left to
bottom right. (0 = not
connected, 1 =
connected)
Crosspoints are
numbered column by
column from top left to
bot- tom right.
matrix
2017.05 | 3.20 | F.01U.119.956