Bosch IRIS-Net User Manual page 470

Table of Contents

Advertisement

IRIS-Net
Commands for Expander
/
/DSP
/
PARA
EXPANDE
M
R_x
Bosch Security Systems B.V.
Read Write
/ATTACK
/
R / W
VALUE
/BYPASS
/
R / W
VALUE
/
/
R
GAINRED
VALUE
UC- TION
/
/
R / W
MAKE_UP
VALUE
_GAIN
/RATIO
/
R / W
VALUE
/RELEASE /
R / W
VALUE
/
/
R / W
THRESHO
VALUE
LD
Values
Description
5...150
Attack time in ms
0, 1
0 = Bypass not activated, 1 = Bypass
activated
Gain reduction as full scale value (32
bit)
Transform given value into dB by: 20
log (0x7FFFFF/ value)
-18...6
Gain of compressor output in dB, not
available for RCM24 compressor
1...10
Compressor ratio
10...1000 Release time in ms
-84...-25
Threshold in dB