Bosch IRIS-Net User Manual page 378

Table of Contents

Advertisement

IRIS-Net
0.0 dB
0.0 dB
Time Constants
Bosch Security Systems B.V.
-80...+18.0
The fader display shows the numerical value of the current
dB
fader setting and additionally provides the possibility for
entering a desired value.
Indicates the current input level.
CAUTION: The Meter is only active, if the check box AUTO of
the input is selected.
MUTE button for muting the corresponding input signal.
INV button for inverting the input channel.
SOLO button for monitoring a single input signal.
PRIO button for increasing priority (= higher level) of input
signal.
Text field for labeling an input channel with an internal IRIS-Net
name.
CAUTION: The use of*(asterisk) and = (equal) in names is not
permissible.
Opens the Time Constants dialog.
-80...+18.0
Fader for setting the level of signal OUT. The meter indicates
dB
the current output level.
By pressing FREEZE GAIN the current input signal gain settings
are stored and remain constant even if the level of the input
signals changes.
User Manual
DIGITAL MATRIX | en
378
2017.05 | 3.20 | F.01U.119.956

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents