Bosch IRIS-Net User Manual page 225

Table of Contents

Advertisement

IRIS-Net
...
/TX5
/LAST
/STFLAG /DEVICE
/IN_A
Bosch Security Systems B.V.
/FNCT
/INV
/PRM
/...
...
/RX
/TX
/ACT
/
COLLE
CT
/ACT
/
COLLE
CT
R / W
NOTHING,
POWER,
ABS, TEMP,
VU, CTL_IN,
ERR- FLAG,
MEMFLAG,
PRESET
R / W
ON, OFF
R / W
0000...03FF
R / W
0000...03FF
R / W
see table
Device State
Flags
R / W
R / W
see table
Input
Channel
Flags
R / W
User Manual
REMOTE AMPLIFIER | en
Condition that triggers the transmission
of a job code. For further details please
refer to table "Job Codes - Transmit
Functions" on this page.
Inverts the result of the programmed
condition
Parameters and values for functions
mentioned above
(same as above but for transmitting Job
Codes 2 to 5)
The ID (hex code) of the last received
job code is displayed during reading.
Writing simulates the reception of a job
code with the stated ID (hex code) by
the power amp.
The ID (hex code) of the last transmitted
job code is displayed during reading.
Writing transmits a job code with the
stated ID (hex code).
Commands for Error and Status
Requests
List of currently set status and error
flags of device. Writing resets some
flags.
Flag template for Collected Error Flag (a
list of status and error flags as
mentioned above).
The state is buffered (Hold function)
when COLLECT is listed in the template.
List of currently set status and error
flags of input A. Writing resets some
flags.
Flag template for Collected Error Flag (a
list of status and error flags as
mentioned above).
The state is buffered (Hold function)
when COLLECT is listed in the template.
2017.05 | 3.20 | F.01U.119.956