0.0 dB
0.0 dB
LINE/MIC
MESSAGE MANAGER
The Message Manager block provides access to the messages of the internal Message Manager. Double click the block
to open the Message Manager dialog.
Notice!
Recorded messages
The recorded messages are displayed in the Message Manager dialog only in online mode. To
download the recorded messages to your PC open following address in your web browser: http://
<ipAddressOfController>:8080/mm2/messages.html
Element
Description
MESSAGES
Active
Indicates the messages that are currently active (marked with a "X").
Description
The unique name or description of the uploaded message. Use the corresponding text field to
edit the description. The description can be edited in offline or online mode. For recorded
messages the description is "Voice Alarm Rec. [date/time]".
Type
Available message types for uploaded messages are EVAC, Chime or Business. The Type can be
set when adding messages. For recorded messages the type is "VA Rec".
Duration
The duration of the uploaded message, given in format "minutes:seconds".
Level
Indicates the level of the message. Level ranges from -80 dB to +18 dB. Default level is 0.0 dB.
Use the corresponding spin control to edit the level. The level can be edited in offline or online
mode.
Bosch Security Systems B.V.
The +48V button of the MIC/LINE input channels is for activating
phantom power whenever a suitable condenser microphone is being
used.
-80 to +18.0
Fader for setting the input level.
dB
-80 to +18.0
The fader display shows the numerical value of the current fader setting
dB
and additionally allows entering a desired value.
The PLT button activates (engaged) or deactivates (not engaged) pilot
tone detection. The PLT button lights red when pilot tone detection is
active but without a pilot signal being detected. With a pilot signal
present, the PLT button lights green.
MUTE button for muting the input signal.
Press the LINE button if the line level audio input (LINE port) of the call
station is used. Press the MIC button if the microphone of the call
station is used, this loads a preset for the input 3 Band PEQ and
Compressor of CST1-4.