Bosch IRIS-Net User Manual page 789

Table of Contents

Advertisement

IRIS-Net
Keyword
Values
OpenIntActive
0, 1
OpenIntPort
Following table lists the default setting of the Controller's Ethernet port.
Parameter
IP address
Network mask
Standard gateway
Port
HINT: Only one single Ethernet connection can be used at one time.
HINT: The password protection of the ASCII Control Protocol can be configured at the Interfaces dialog of the
Controller.
ZONE STATUS
Whenever the output status of the local zones changes, a zone status string is sent via the ASCII Control Protocol. The
format of the zone status string is: <Idx.y> <Change> <Pm> <Zone Pattern>
Element
Description
Idx.y
Unique identifier:
x is the number x in the IRIS-Net internal device name, e.g. „Device_x"
y is a unique paging request number of the local Controller
Change
ON, if the paging request Idx.y has activated one or more local audio outputs of the Controller
OFF, if the paging request was terminated and the corresponding local audio outputs of the
Controller have been deactivated
Pm
Priority of the paging request
Zone Pattern
List of activated local zones of the Controller.
Examples:
Id3.7 ON P12 Z2-3
Id3.7 OFF
Notice!
The zone pattern lists the zone numbers, this numbers can be found in the Line Supervision table
of the DPM 8016
Bosch Security Systems B.V.
Default
Description
0
This keyword allows activating or deactivating the ASCII
Control Protocol. If deactivated, a connection via Ethernet is
not possible.
OpenIntActive = 1: The ASCII Control Protocol is activated
OpenIntActive = 0: The ASCII Control Protocol is not
activated
6273
The Ethernet port for the TCP connection between the
Controller and the external device.
Default
192.168.1.100
255.255.255.0
192.168.1.1
6273
User Manual
PROMATRIX 8000 | en
789
2017.05 | 3.20 | F.01U.119.956