Bosch IRIS-Net User Manual page 841

Table of Contents

Advertisement

IRIS-Net
AMP INPUTS
PILOT DETECTION x-
IN1
PILOT DETECTION x-
IN2
PILOT DETECTION A-
S1
PILOT DETECTION B-
S2
EXTERNAL
CALL STATIONs
A connected DPC call station has transferred an error message. The parameter
%u gives the address of the erroneous call station.
AMPLIFERS
A connected DPA power amplifier has transferred an error message. The
parameter %u gives the address of the erroneous amplifier.
ROUTERS
A connected DCS system has transferred an error message. The parameter %u
gives the address of the erroneous DCS system.
POWER SUPPLY
Fault condition in the power supply of the PMX-4CR12. "ALL" switch button
control can be used to activate system-wide collection for this fault on the
controller.
SPEAKER LINE
Fault condition in the speaker line supervision.
FAULT
The parameter %u gives the number of the erroneous speaker line, the number
has the following meaning:
1 to 500: Zone A
501 to 1000: Zone B
"ALL" switch button control can be used to activate system-wide collection for
this fault on the controller.
USER
USER FAULT 1 to
One or more USER FAULTS have been set
10
HINT: Use the device Task Engine to configure USER FAULTS.
MASTER
COMBINED FAULT
STATE
SYSTEM
SYSTEM FAULT
SYSTEM COMBINED FAULT
Bosch Security Systems B.V.
Missing pilot tone at input 1 of cluster A or B.
Missing pilot tone at input 2 of cluster A or B.
Missing pilot tone at spare input 1 of cluster A.
Missing pilot tone at spare input 2 of cluster B.
The FAULT indicator light on the front panel of the device lights at the occurrence of this type
of error.
Manually setting or resetting an error.
Active if any system fault is active in the system. "ALL" switch button control
can be used to activate system-wide collection for this fault on the controller.
Active if any COMBINED FAULT STATE is active in the system.
User Manual
PROMATRIX 6000 | en
841
2017.05 | 3.20 | F.01U.119.956

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents