Output And Transmit Job Conditions - Bosch IRIS-Net User Manual

Table of Contents

Advertisement

IRIS-Net
Measurem
Generator
ent
frequency,
Time, Level A /
B
Test
Channel, Signal
generator
type,
Frequency,
Solo/Pre, Level
Output and Transmit Job Conditions: The following table lists all amplifier statuses that can be used for triggering
control outputs or for sending Transmit Job Codes.
Function
Parameter
Empty
-
Power
Absolute
all DSP parameters
Temp
Temperature in °C
VU
IN A, IN B, OUT A, OUT B,
Limiter A/B,
Compressor A/B
GPI
IN 1, IN 2
Errorflag
All internal fault
conditions
Memoflag
Enable for selected flags
as well as bit- pattern of
flags 1 - 16
Preset
U01 - U08, F01-F02, O01-
O02
DSP
The DSP pages provide overview and access to all DSP parameters of an amplifier. Within this window you can use the
Flow Diagram Selector to link to different function groups.
FLOW DIAGRAM SELECTOR
The Flow Diagram Selector can be accessed from any DSP page offering navigation means within the DSP signal
processing functions. The Flow Diagram Selector lets you select different function blocks, where the actually selected
block is displayed in a yellow engaged field.
Bosch Security Systems B.V.
Starts measurement with a tone signal of the specified frequency at
the levels specified for channels A / B for the selected duration (0 ms
= infinite)
Starts the test generator with selected signal type or of the specified
frequency at the levels specified for channels A / B for the selected
duration (0 ms = infinite)
Opt.Value
Invert
-
X
Corresponding
Parameter Value
X
(parameter-
dependent)
X
Level in dB
X
X
X
X
X
User Manual
REMOTE AMPLIFIER | en
Triggering Event/Status Change
Not configured
Power On
Power Off (Standby)
Set parameter value reached or exceeded
Set parameter value declined
Set temperature reached or exceeded Set
temperature declined
Set level reached or exceeded Set level
declined
Control input 1 / 2 closed (ON) Control input
1 / 2 open (OFF)
Single or several error flags set None of the
selected error flags set
Memory flags match the selected bit-pattern
Memory flags do not match the selected bit-
pattern
Specified preset selected
Other than the specified preset selected
2017.05 | 3.20 | F.01U.119.956