Bosch IRIS-Net User Manual page 496

Table of Contents

Advertisement

IRIS-Net
Master Fault
Error
Collected Error State
Audio Processing
Remote Amplifiers
Audionet
DPM 4000
CAN Bus
Slave Devices
User Fault
Watchdog from Master
AD Converter
Supply Voltages
GPI
RS-232 Ports
Configuration Data
Fault
Hardware
Configuration
Bosch Security Systems B.V.
Description
The FAULT-LED on the front panel of the N8000 lights at the occurrence of this error.
General DSP fault, please refer to the table DSP Faults for further detail
General Remote Amplifier fault, please refer to the table RCM Faults for further detail
Error within the Audionet-System (CM-1, DM-1, OM-1)
The DPM 4000 connected to the RS-232 port cannot be accessed
General CAN Bus error, please refer to the table RCM Faults for further detail
A Remote Device signals an error or cannot be accessed
The Error Code of at least one User Fault has been set to ≠ 0
The Heartbeat Timer's time limit has been exceeded
Malfunction in the A/D converter of control inputs (GPI)
Error in the N8000's internal power supply
The input voltage of a control input (GPI) is to low/high
A unit connected to the RS-232 shows a malfunction
Memory/Configuration data error, please refer to tables DSP Faults and RCM Faults for
further detail
Hardware Configuration fault in the N8000, please refer to table DSP Faults for further detail
User Manual
DIGITAL MATRIX | en
496
2017.05 | 3.20 | F.01U.119.956