Bosch IRIS-Net User Manual page 910

Table of Contents

Advertisement

IRIS-Net
NOTIFICATON
At the occurrence of a type of error for which the checkbox DETECT is ticked, the
COLLECTED ERROR STATE flag is set at the same time. Additionally the FAULT
indicator light on the front panel of the controller lights, the FAULT relay opens
and a signal sound.
CONTROLS
Error types
DEVICE
CAN connection between Controller and Amplifier broken.
CONNECTED
MEMORY
Memory error.
WATCHDOG
Watchdog error of the device. This error type is logged conforming to standards,
press the CLEAR button to reset the error.
FIRMWARE
The firmware version is not compatible with the IRIS-Net version used. A firmware
update is recommended.
PROTECT
Protect mode of amplifier activated.
OVERHEAT
Temperature overload of the device.
POWER SUPPLY
Error in the mains power supply of the device.
MAINS
POWER SUPPLY
Error in the battery power supply of the device.
BATTERY
OUTPUT PILOT
Missing pilot tone at the amplifier output channel 1 or 2.
DETECTION
INPUT x PILOT
Missing pilot tone at the amplifier input channels 1 to 4.
DETECTION
MASTER
COMBINED FAULT
STATE
Bosch Security Systems B.V.
The FAULT indicator light on the front panel of the device lights at the occurrence of this type
of error.
Manually setting or resetting an error.
User Manual
PROMATRIX 6000 | en
910
2017.05 | 3.20 | F.01U.119.956

Hide quick links: