IRIS-Net
Channel Parameters
Element
Description
Description of the FIR filter currently in use.
After clicking onto LOAD the "Open File..." dialog box appears. Enter the correct path of the
directory in which the desired file is located and select the desired FIR file to be opened. This loads
and afterwards displays all FIR filter parameters that are stored within that file.
CAUTION: The loaded FIR filter file becomes instantly audible when in on-line mode. Be sure to
select the desired FIR file with the correct set of parameters. In the worst case, this could lead
to severe damage to the connected loudspeaker cabinets due to improper signal processing!
After clicking on EXPORT FIR a "Save File..." dialog box appears. Enter the correct path of the
directory that you want to save the data in. Enter a file name (without extension). Click on the SAVE
button to store the FIR filter parameters together with the corresponding file name. ".gkf" is
automatically added as file extension.
Clears the current FIR filter settings. A Default-FIR-Filter (Thru) is activated instead.
Clicking on the NEW button opens the Filter Design dialog.
Press the ACTIVE button to deactivate the filter (Bypass), which allows for quick A / B-evaluation of
the actual effect that the filter has on the sound.
Adjusts the gain of the signal between -30 dB and +6 dB.
The fader display shows the numerical value of the current fader setting.
Clicking the MUTE button with the left mouse button mutes the corresponding output. The MUTE
button is virtually pressed and lights red. Clicking the MUTE button once again with the left mouse
button disables the mute-function and the output is again active. The MUTE button is virtually
disengaged and not lit.
Bosch Security Systems B.V.
User Manual
REMOTE AMPLIFIER | en
2017.05 | 3.20 | F.01U.119.956