DSP 244 USERPANEL
The DSP 244 Userpanel provides access to the controls and indications at the DSP 244 front panel. The complete
functionality available at the DSP 244 LC-Display can be accessed via pressing the DSP button.
Indications and Functions of the DSP 244 Userpanel
Element
Description
The level meter instruments are meant for optical monitoring of the input signal levels, individually
showing the peak value of the correspondent input signal. The input control should be set to a
position so that the meter instruments indicate a level between -6 and -12 dB. To prevent inter- nal
clipping, make sure that the CLIP LEDs are not lit.
Line 1 displays the description of the selected User Memory. Line 2 displays the description of the
device and its address at the RS-485 bus.
These LEDs indicate, which frequency band the corresponding channel is set to. If a channel is
configured for full range operation, all its func- tion-LEDs are simultaneously lit.
These keys allow to mute the output signal of the corresponding output channels. Pressing a key
once switches the mute-function ON; the key's red LED lights. Pressing the button again switches
the mute-function OFF; the key's LED is dimmed again.
Bosch Security Systems B.V.
User Manual
DIGITAL SOUND PROCESSOR | en
2017.05 | 3.20 | F.01U.119.956