Default
CST 1-4, MIC/LINE
1-2, AUX 1-2
LINE/MIC
PEQ
0 dB
125 Hz, 1
kHz, 16 kHz
0.7
6dB/Oct
Bosch Security Systems B.V.
Range
Description
Press the input channel button to view or edit the
corresponding PEQ settings.
Press the LINE button if the line level audio input (LINE port)
of the call station is used. Press the MIC button if the
microphone of the call station is used.
Pressing BYPASS ALL switches off all filters.
Name of the corresponding filter band. Clicking with the right
mouse button onto this field opens Copy & Paste menu,
which allows comfortably copying all EQ parameters of the
selected filter to any other EQ within the same project.
PEQ. Loshelv.
TYPE defines the filter type.
Hishelv, Hipass,
Lopass
-18 to +12 dB
GAIN defines the amplification (increase) or attenuation
(reduction) of parametric EQs or low shelving and high
shelving equalizers.
20 Hz to 20 kHz
FREQ (frequency) sets the center frequency of a parametric
EQ or the cut-off frequency of shelving and Hi / Lo pass
filters.
0.1 to 100 (PEQ)
Q defines the quality or bandwidth of a parametric EQ. A high
0.1 to 2.0 (Hi-/
Q-value results in a narrowband filter, while a small Q-value
Lopass)
results in a broadband filter. The Q-value also sets the quality
and thus the response of Hi and Lo pass filters with slopes of
12dB/ oct.
6dB/Oct,
SLOPE sets the steepness or filter-order of low or high
12dB/Oct
shelving equalizers and low or high pass filters. Setting
different slopes within the transmission range is possible.
That, in conjunction with the Q-parameter, offers the
possibility for a hi-pass filter to be programmed for B6-
alignment, which describes a drastic rise in the cut-off
frequency range.
BYPASS switches the corresponding filter ON (not engaged)
or OFF (engaged), which allows for quick A / B-evaluation of
the actual effect that a filter has on the sound.
User Manual
PEQ is a parametric Peak Dip Filter with its frequency,
quality (Q) and gain being programmable.
Loshelv / Hishelv create a Low-Shelving or High-Shelving
filter with the parameters being: frequency, slope and
gain.
Lopass / Hipass creates a Low Pass or High Pass filter
with adjustable frequency and slope.