Bosch IRIS-Net User Manual page 443

Table of Contents

Advertisement

IRIS-Net
Element
Default
PEQ
0 dB
depends
on
number
of filters
Bosch Security Systems B.V.
Range
Description
Switch for displaying amplitude frequency response (magnitude) or
phase response (phase)
Switch for scaling the amplitude axis to 25 dB (± 12.5 dB) or 50 dB (±
25 dB)
Switch for changing between bandwidth BW and Quality Q when
setting employed filters.
Pressing BYPASS ALL switches of all filters.
Name of the corresponding filter band. Clicking with the right mouse
button onto this field opens Copy & Paste menu, which allows
comfortably copying all EQ parameters of the selected filter to any
other EQ within the same project.
PEQ.
TYPE defines the filter type.
Loshelv.
PEQ is a parametric Peak Dip Filter with its frequency, quality (Q)
His- helv,
and gain being programmable.
Hipass,
Loshelv / Hishelv create a Low-Shelving or High-Shelving filter
Lopass,
with the parameters being: frequency, slope and gain.
Allpass
Lopass / Hipass creates a Low Pass or High Pass filter with
adjustable frequency and slope.
Allpass is a filter that has no influence on the frequency response
but on the phase response in the transmission function.
-18...+18
GAIN defines the amplification (increase) or attenuation (reduction) of
dB
parametric EQs or low shelving and high shelving equalizers.
20 Hz...20
FREQ (frequency) sets the center frequency of a parametric EQ or the
kHz
cut-off frequency of shelving and Hi / Lo pass filters.
User Manual
DIGITAL MATRIX | en
443
2017.05 | 3.20 | F.01U.119.956

Hide quick links:

Advertisement

Table of Contents
loading