Enter the required number of devices and select a communication interface. Click on the OK button to accept these
settings. The specified number of P 64 devices will be created and displayed in the worksheet. Selected devices can be
dragged around and repositioned at will. To select a device either click and drag the mouse to draw a rectangle around
it or hold down the 'ctrl' key and click on the device. In either case a successfully selected device is shown with a red
border around it.
Double clicking on an P 64 device icon opens the configuration dialog window. Double clicking on a device for the first
time will open the General dialog box. Here, you can specify initial settings that are necessary for further configuration
and communication. Additional configuration windows can be navigated to by clicking on the icons at the top of the
window. However, as a basic rule, IRIS-Net will remember which window was used last and reopen to this window next
time you double click on the P 64 device icon.
The following table lists all available P 64 dialogs with a short description for each. For more detailed information,
please refer to the appropriate chapters.
Dialog
Description
General
This window allows hardware settings to be configured, e.g. input/output module
slots, network settings, device name, system time and firmware version.
DSP
The DSP window lets you configure all DSP-parameters of the P 64.
Audio Net
This window provides detailed information and configuration of the CobraNet
CM-1 module or Dante DM-1 module.
Interface
From this window the P 64 CAN bus, RS-232 ports and GPIO control port
interfaces can all be configured.
HINT: Ethernet interface settings are explained under General dialog in the
paragraph Network Settings.
Supervisio
This window provides an overview of the operational state and current fault
n
status of the P 64.
Task
This window lets you configure the P 64 Task Engine.
Engine
General Dialog
Double clicking on a P 64 by default opens the General dialog box. Here, the user can make basic settings that are
necessary for flawless operation. All elements of the displayed P 64 front panel are active in on-line mode and
correspond to the actual indicators on the unit.