Examples:
/POWER/SWITCH ON ; switches amp's power on
/TEMP/MODULE ? ; queries the remote control module temperature
/TEMP/MODULE 65 ; reply to query: 65 °C
/STFLAG/DEVICE/ACT ? ; queries operational state and error flags
/STFLAG/ACT POWER,GLOBAL ; reply to query: Power is On, Global Error detected (Collected Error in external
CAN-devices)
/STFLAG/GLOBAL ? ; queries for which external CAN-devices errors have been detected
/STFLAG/GLOBAL 3-4 ; reply to query: Collected Error Flags on amps 3 and 4 are set
DSP PARAMETER INDEX TABLE
Input channel A or B
Index
Parameter Description
/IDX00
delay bypass
/IDX01
delay
/IDX02
eq1 bypass
/IDX03
eq1 type
/IDX04
eq1 slope
/IDX05
eq1frequency
/IDX06
eq1 gain
/IDX07
eq1 quality
/IDX08
eq2 bypass
/IDX09
eq2 type
/IDX0A
eq2 slope
/IDX0B
eq2frequency
/IDX0C
eq2 gain
/IDX0D
eq2 quality
/IDX0E
eq3 bypass
/IDX0F
eq3 type
/IDX10
eq3 slope
/IDX11
eq3frequency
/IDX12
eq3 gain
/IDX13
eq3 quality
/IDX14
eq4 bypass
Bosch Security Systems B.V.
Value Range
Value Description
0 / 1
0 = ON, 1 = BYPASS
1.68467...2000
ms
0 / 1
0 = ON, 1 = BYPASS
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
0...2
0 = 0dB bypass, 1 = 6dB, 2 = 12dB
20...20000
Hz
-18...12
dB
0.4...40
0 / 1
0 = ON, 1 = BYPASS
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
0...2
0=0dB bypass, 1=6dB, 2=12dB
20...20000
Hz
-18...12
dB
0.4...40
0 / 1
0 = ON, 1 = BYPASS
0...5
0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
0...2
0=0dB bypass, 1=6dB, 2=12dB
20...20000
Hz
-18...12
dB
0.4...40
0 / 1
0 = ON, 1 = BYPASS