IRIS-Net

N8000 and P 64

The following chapters are valid for N8000 and P 64.
DSP blocks
The library that holds all available DSP blocks (Processing Objects) is located on the left hand side of the DSP window.
The DSP blocks are separated into groups or categories. Clicking on a group opens that group and provides access to
the DSP blocks that are located inside. You can drag the desired DSP blocks from the list on to the worksheet, where
they can be freely positioned and/or virtually wired with other blocks.
The available DSP blocks are summarized in following table.
Category
Description/
Definition
Crossover
n-Way
Crossover
n-Way Stereo
Crossover
Delay
Mono Delay x
ms
Bosch Security Systems B.V.
Input
Outputs Description
s
1
1
Crossover blocks in Mono/Stereo with 1 to 5 channels.
Each crossover channel has a High Pass and a Low Pass
2
with the following parameters: type, frequency, polarity,
3
level and mute.
4
5
2
2
4
6
8
10
1
1
Delay blocks in Mono/Stereo with 10, 100, 500 or 2000 ms
maximum delay. Entering values for distance and ambient
temperature is possible.