User Fault: It is possible to select a User Fault on which a condition depends. The conditions result is true (or false
when choosing Invert Condition instead) once the User Fault occurs.
HINT: A User Fault occurs if the associated Error Code is not equal 0. The User Fault macro is always used when
setting a User Fault.
Example:
The screenshot on the left shows the condition "UserFault2OK". This conditions result is true if the User Fault 2 has not
been set, i.e. its Error Code equals 0.
Temperature: The temperature within the N8000 System Controllers enclosure is constantly being monitored. The
condition depends on the compliance with upper and lower thermal thresholds. Limit values have to be entered in °C.
The conditions result is true (or false when choosing Invert Condition instead) as long as the actual temperature stays
within the defined temperature range.
HINT: Converting temperature values from degrees Fahrenheit °F to degrees Celsius °C is done according to the
following formula: degree Celsius = (degree Fahrenheit - 32) * 5/9
Example:
The screenshot on the left shows the condition "Temp High". This conditions result is true as long as the temperature
stays above the maximum allowable temperature of 50°C.