Bosch IRIS-Net User Manual page 840

Table of Contents

Advertisement

IRIS-Net
CONTROLS
CST TEXT
If call stations are configured for error indication, the text entered here is
indicated in the call station display if the error occurs. The maximum number of
characters is 11 when using system languages Korean or Chinese. The maximum
number of characters is 20 when using other system languages.
HINT: The meaning of the parameter %u is described at the error types below.
INTERNAL
MEMORY/DATA
Memory or Read/Write error.
WATCHDOG
Watchdog error of the device. This error type is logged conforming to standards,
press the CLEAR button to reset the error.
FIRMWARE
The device firmware version is not compatible with the IRIS-Net version used. A
firmware update is recommended.
HARDWARE
Error in the power supply or the A/D converters of the device.
TEMPERATURE
Temperature overload of the device.
Temperature
Current temperature inside of the device (main board).
control
AUDIO
Error during the processing of audio data.
PROCESSING
MESSAGE
Error in the message manager.
MANAGER
INTERFACES
CAN BUS
Fault condition on the CAN bus. Further details are provided in the Interface
dialog.
CST INTERFACE
Fault condition on the PCA bus. Further details are provided in the Interface
dialog. The parameter %u gives the slot number of the erroneous module.
AUDIO NET
Fault reflecting the collected error state in the AudioNet tab.
INT. ROUTER
DSP
HARDWARE
PG / LT
TEMPERATURE
GPI SUPERVISED
Bosch Security Systems B.V.
Error in the digital signal processing (DSP) of the device.
Hardware error.
Temperature overload of the device.
Voltage at supervised GPI out of range.
User Manual
PROMATRIX 6000 | en
840
2017.05 | 3.20 | F.01U.119.956