Bosch ICP-MAP5000-2 Installation Manual
Bosch ICP-MAP5000-2 Installation Manual

Bosch ICP-MAP5000-2 Installation Manual

Map 5000 series main panel intrusion alarm system
Hide thumbs Also See for ICP-MAP5000-2:
Table of Contents

Advertisement

MAP 5000
ICP-MAP5000-2 / ICP-MAP5000-COM
en
Installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch ICP-MAP5000-2

  • Page 1 MAP 5000 ICP-MAP5000-2 / ICP-MAP5000-COM Installation manual...
  • Page 3: Table Of Contents

    3.10.1 Mounting 3.10.2 Connection 3.10.3 Programming instructions for ISP-EMIL 120 3.11 Final power connections 3.12 IP Interface Initial set-up and programming Initial set-up Programming 4.2.1 Help for the programming software Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 4 Requirements in accordance with SES 8.3.1 Selecting the default setting 8.3.2 Automatic arming / disarming 8.3.3 Areas with blocking time 8.3.4 Access Levels 8.3.5 Tamper surveillance of the main panel Alarm reporting 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 5: Introduction

    When installing this system, ensure that all local and national wiring codes are met. – Only authorized service personnel is allowed to install this system. – Use only the installation material recommended by BOSCH Security Systems to ensure error-free operation. – Follow anti-static procedures when handling system components. Ensure that you are properly grounded to discharge any static charge before you work with system components.
  • Page 6: Planning The System

    Four batteries (maximum 40 Ah each) This module mounts on the ICP-MAP0025 hinged mounting plate. This module mounts on the ICP-MAP0020 accessory mounting plate, which mounts to the back of the enclosure. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 7: Planning The System With Ipp-Map0005 Power Supply

    The following conditions must be taken into account when planning in order to guarantee a reliable system booting: Condition 1 3-wire cables are always used for connections between power supply segments (without +28 V, red wire) Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 8 Refer to , page 10. Typical configuration with ICP-MAP0111 panel enclosure Main panel - DE module - 3 LSN gateway modules - max. 2 control centers ICP-MAP0111 Figure 1.3: Wiring with ICP-MAP0111 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 9 Short-time current limitation to 3.2 A per output A / B Cable length The maximum number of control centers that can be supplied by one power supply depends greatly on the length and diameter of the cable used. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 10: Planning The System With Icp-Map0012 Can Splitter Module

    When using a CAN splitter module to split the external BDB into two independent areas, chose one of the following wiring possibilities: Wiring with a CAN splitter module and a MAP LSN gateway module ICP-MAP0012 ICP-MAP0010 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 11 These cable lengths apply for keypads that are mounted with an equal cable distance in between each other. See also – Splitting the external data bus with a CAN splitter module, page 43 Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 12: System Overview

    This chapter shows an overview of the system as it is installed in the ICP-MAP0111 control panel enclosure. System installation in ICP-MAP0111 panel enclosure (hinged mounting plate closed) ICP-MAP0111 System installation in ICP-MAP0111 panel enclosure (hinged mounting plate open) ICP-MAP0111 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 13 System installation in ICP-MAP0120 expansion enclosure Enclosure overview ICP-MAP0111 Element Description Wire trays Wire knockouts Mounting rails for ICP-MAP0020 accessory mounting plate Mounting location for TAE box Knockout for wall tamper Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 14 Mounting location for ICP-MAP0065 AC terminal block Earth ground connection points Flange for IPP-MAP0005 power supply Shielding connection points Knockout for AC wires (use when AC wires come in from the back of the enclosure) 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 15: Installation

    Remove the enclosure knockouts in the order shown in the figure below. Enclosure knockouts ICP-MAP0111 Element Description Knockout for wall tamper (required in accordance with EN50131 grade 3) Knockout for TAE box Knockouts for wiring Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 16: Installing The Tamper Switch Rail

    Mount the tamper switch rail to the inner right side of the enclosure as shown in the figure below. Secure the tamper switch rail with the two supplied screws. Do not mount the tamper switch at this time. Mounting the tamper switch rail ICP-MAP0111 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 17: Mounting The Enclosure

    Mount the enclosure to the intended surface using suitable screws and anchors (not supplied). Use the mounting holes as shown in the figure below. Ensure that all screws are tight and that the enclosure is securely fastened to the mounting surface. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 18 Mount the edge protection profile on the upper edge of the MAP enclosure from the left to the right. Ensure not to leave gaps at the cut-outs. Cut off the overlaying edge protection profile on the right side of the enclosure. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 19: Checking The Ac Connection

    Align the cut-out on the right side of the power supply. Secure the power supply to the enclosure back wall with the supplied hardware in the following order: external tooth washer, washer, hex nut Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 20 Installing the power supply ICP-MAP0111 IPP-MAP0005 Refer to IPP-MAP0005 power supply ratings label, page 21 for the location of the power supply ratings label. Refer to Technical Specifications, page 69 for power specifications. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 21 Plug the terminal block connected to the AC terminal block into the power supply as shown in the figure below (2). Connect the ground wire to the ground connection point of the enclosure back wall as shown in the figure below (3). Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 22: Installing The Tae Box

    Installing the TAE box If the TAE Box is not mounted on the wall behind the enclosure, mount the TAE Box to the enclosure back wall either horizontally or vertically as desired. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 23: Installing The Accessory Mounting Plate

    Slide the clips on the back of the accessory mounting plate onto the top and bottom mounting rails. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 24 Ensure that the locking clips snap into the bottom mounting rail as shown in the figure below. Installing the accessory mounting plate Refer to Accessory mounting plate overview, page 25 for the locations of the modules that mount on the accessory mounting plate. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 25: Installing The 12 V Converter

    (screws not supplied). Connect the field wiring to the terminal block of the 12 V converter as shown in the figure below and leave the other ends unconnected. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 26: Installing The Fuse Plate (Siv)

    Use the corresponding ratings for the fuses SI 1 ... SI 5. (minimum 250 mA, maximum 1 A depending on the connected loads). The overall current of all SIV outputs must not exceed the available maximum current of the voltage output used. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 27: Installing The At 2000 Communicator

    Notice! To ensure proper system grounding, you must insert the grounding screw through the AT 2000 and the accessory mounting plate. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 28 AT 2000 also requires a separate 12 V power source, such as the ICP-MAP0017 12 V converter. The ISDN AT 2000 requires 28 V. Use the ribbon cable connector labeled AT 2000 28V. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 29 Analog AT 2000 to DE module connections Notice! The two trouble inputs are automatically configured to "Communicator Trouble" and "Negative Acknowledgment" when "Communicator" is selected in the Remote Programming Software (RPS). Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 30 | Installation MAP 5000 Analog AT 2000 to ICP-MAP0017 12 V converter connections 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 31 MAP 5000 Installation | en AT 2000 ISDN to DE module connections Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 32: Installing The Hinged Mounting Plate

    Installing the hinged mounting plate ICP-MAP0111 ICP-MAP0025 Mounting modules onto the hinged mounting plate The following graphic shows an overview of the hinged mounting plate and the designated mounting locations of the modules. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 33 Hinged mounting plate overview ICP-MAP0007 ICP-MAP5000 ICP-MAP0025 ICP-MAP0010 ICP-MAP0012 Slide the module onto the hinged mounting plate. Ensure that the locking clips snap into a pair of rectangular openings on the bottom rail. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 34 | Installation MAP 5000 Sliding the module onto the hinged mounting plate Connect the grounding cable from the enclosure back wall to the hinged mounting plate. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 35: Mounting The Main Panel

    2.12 Mounting the main panel This chapter describes the mounting of the following main panels: – MAP Main Panel (ICP-MAP5000-2) – MAP Main Panel with IP Communicator (ICP-MAP5000-COM) including the MAP GSM module (ITS-MAP0008). How to mount the main panel The main panel is mounted on the hinged mounting plate.
  • Page 36: Installing The Icp-Com-If Relay Module

    Attach the carrier plate of the ICP-COM-IF relay module in the holes provided in the hinged mounting plate or the mounting rails. Use the screw provided to secure the carrier plate to the bottom rail. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 37: Installing And Connecting The Its-Map0008 Wireless Modem

    Warning! In order to avoid data loss on the SIM card, the wireless modem must be de-energized before inserting or removing the SIM card. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 38: Antennas

    Max power: 10 W Radiator length: 100 mm Foot: 34 mm Magnetic antenna mast incl. bottom with 2.6 m cable. The FME female connector is preconfigured on the coaxial cable. Rod antenna 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 39 Area of use: inside, outside Rod antenna incl. 20 m cable. The mounting bracket is designed for mounting on vertical surfaces, the FME female connector is preconfigured 1) not for VdS Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 40: Connections

    Always use the main panel as the first device on the data bus. The 120 ohm end terminator is already installed on every data bus. Connect a 120 ohm end terminator to the last device on each data bus. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 41 The order of system modules on the BDB shown in the figure is not mandatory. A symmetrical load distribution to the power supply outputs A and B must be ensured as far as possible. Data bus cable routing 120 Ω Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 42: Internal / External Data Bus

    BDB. 3.1.2 Topology of the external data bus Mount the external BDB as shown below. Notice! Any other bus topology doesn’t conform to the specifications of the BDB. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 43: Splitting The External Data Bus With A Can Splitter Module

    Only assign one area (where applicable with overlapping dependent partition areas) to a control center. Exception: Mutually independent areas may be assigned to the control center of the control panel area. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 44: Connecting The Main Panel

    Data bus connection of the control center on the external BDB Connecting the main panel This chapter describes the connection of the following main panels: – MAP Main Panel (ICP-MAP5000-2) – MAP Main Panel with IP Communicator (ICP-MAP5000-COM) including the MAP GSM module (ITS-MAP0008).
  • Page 45: Connecting The Power Supply

    Mount the thermistor inside the enclosure. Connect the AC terminal block to the power supply. Connect the power supply to the main panel using the supplied four-pin connector cable (P/N: F01U074769). Mounting the thermistor Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 46: Connecting The Lsn Gateway

    The outputs AUX1 and AUX2 on the LSN gateway (for max. two areas) or the voltage outputs of the fuse plate (SIV) (for additional areas) are available for this purpose. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 47 Other connections of the additional shielding wire at other locations are not permitted. With loop wiring, the additional shielding wire must be connected at both loop ends. LSN gateway loop configuration ICP-MAP0111 Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 48: Optional Connections

    Optional power supply connections Connect the auxiliary DC power for the 12 V converter. Connect the supervision outputs. The supervision outputs monitor AC mains failure and summary power supply trouble. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 49 Connecting the power supply Optional DE module connections If a DR2020 printer is used, connect the DE module to the DR2020. Connect the supervised sirens and strobes to the DE module outputs. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 50: Installing And Connecting The Tamper Switch

    > 5 mm leads to reliable activation of the tamper switch. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 51 Switch to the ICP-MAP5000 main panel. Refer to Connecting the ICP-MAP0050 tamper switch, page 52. For the ICP-MAP0120 enclosure, connect the ICP-MAP0055 expansion enclosure tamper switch to the ICP-MAP0005 power supply. Refer to Connecting the ICP-MAP0055 tamper switch, page 52. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 52: Installing The Icp-Map0060 Enclosure Lockset

    Insert the lockset into the opening on the enclosure door as shown in the figure below (2). Secure the lockset with the nut as shown in the figure below (3). 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 53 MAP 5000 Connections | en Installing the enclosure lockset Connect the long grounding cable (P/N F01U074762) to the enclosure door. Connecting the grounding cable to the enclosure door Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 54: Installing The Control Center

    The maximum cable length between the expansion module and operating panel is 3 m. Mounting Ensure by organizational measures that the operating and display panel is not generally accessible. Use an ISP-EMIL 120 expansion module for activation of the operating and display panel. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 55: Connection

    After wiring, fit the terminating resistors in the expansion module (2 pieces) and in the operating panel (1 piece) (supplied with the expansion module). Connecting the LED panel to ISP-EMIL 120 ISP-EMIL-120 LED-Tableau LSN 3 2 1 Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 56: Programming Instructions For Isp-Emil 120

    Ensure that the AC LED indicator on the power supply turns on steady before you connect the battery terminal to the power supply. Warning! Remove the protective dust cover label from the top of the power supply. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 57: Ip Interface

    In the MAP5000 panel menu, select -> setup: Management system as a Monitoring Station. Notice! Data transfer between the MAP 5000 and the connected PC system must always take place via a secure, authenticated and encrypted connection. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 58: Initial Set-Up And Programming

    Programming is performed with the program RPS for MAP. A PC or laptop with Windows XP SP3, Windows VISTA or Windows 7 is required for this. At least 256 MB RAM is needed. A mouse is recommended for operation of the program. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 59: Help For The Programming Software

    After first start-up, you need to check whether the software versions of all system modules and the programming software are compatible with each other (refer to MAP 5000 system bundles). Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 60: Software Updates

    Overview of the Standard Point Types and their pre-set properties Point Type Arming state differentiation Ready to arm status Armed Disarmed IP Armed consideration (internal) Bolt Contact Duress Fire Hold-up Intrusion 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 61: Output Functions

    (only for panel firmware 1.2.x) Report failure summary alarm Panel has received negative acknowledgment from communicator due to report failure summary alarm Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 62 Reporting of duress alarm event Reportable hold-up alarm Reporting of hold-up alarm event Reportable external intrusion Reporting of external intrusion alarm event, possibly also alarm delayed if present/absent option is used 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 63: Sirens And Communicator In Accordance With En50131 Grade 3

    One communicator class 4 (main communicator) Outputs R1 – R7 on ICP-COM-IF – One communicator class 3 (additional communicator) Outputs R1 – R7 on ICP-COM-IF or other outputs on panel Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 64 | Initial set-up and programming MAP 5000 Notice! Both communicators may be connected to the same outputs. Variant D (ICP-COM-IF required) – One communicator class 5 Outputs R1 – R7 on ICP-COM-IF 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 65: Enclosure Options

    ICP-MAP0065 P/N: F0U124597 ICP-MAP0115 P/N: F0U124597 ICP-MAP0050 BAT1 ICP-MAP0065 BAT2 IPP-MAP0005 Connect the ICP-MAP0115 power enclosure to the ICP-MAP0111 enclosure to provide additional power when high power capacity is required. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 66: Rack Mount Option For Icp-Map0120 Expansion Enclosure

    To install the ICP-MAP0120 expansion enclosure in a 19-inch rack, connect the ICP- MAP0035 rack mount brackets to the ICP-MAP0120 expansion enclosure. Installing the rack mount brackets to the ICP-MAP0120 expansion enclosure 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 67: Maintenance And Service

    Notice! Have maintenance and inspection work carried out regularly by trained expert personnel. Bosch Sicherheitssysteme GmbH recommends performing a functional and visual inspection at least once annually. Danger! Danger of electric shock if live parts are touched. For your safety, you should switch off the...
  • Page 68 Programming, panel firmware and history are deleted and network settings are reset (DHCP, 0.0.0.0) when executing this option. Carry out steps 1 – 6 of the above, then carry out steps 2 – 7. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 69: Technical Specifications

    996 (with 9 digits, supporting a 3-digit user ID (004 - 999) and a 6-digit passcode) Number of possible combination per PINs 1 million Validity of PINs Permanent validity, time-limited validity or one-time use configurable Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 70 1, RJ 45 connection Management system connection Via Ethernet interface and the Open Intrusion Interface OII or the MAP OPC server from Bosch - in VdS systems, only feedback-free connection as information system via exclusive transmission path Number of inputs...
  • Page 71 MAP 5000 Technical Specifications | en Security level IK06 Environmental class EN60950-1 ; EN50130-4 ; EN50131-1 ; VdS 2110 Usage Indoor Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 72: Appendices

    AE 3 Access for installers via control center Open control panel enclosure. Switch to installer mode (refer to Installer button, page 67). Enter installer passcode. AE 3 Access for installers via RPS for MAP 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 73 May change schedule May edit blocking time User category permissions May add user May delete user May change user passcode Event category permissions May clear internal alarm May clear external alarm Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 74 May adjust control center volume/brightness May change output state May set date time May test bell May test motion detectors May walk test automatic points May walk test points Tab. 8.3: Permissions 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 75: Requirements In Accordance With En 50131 Grade 3

    Refer to the manufacturer's connection instructions for further information. 8.2.4 Arming / disarming with entry / exit delay Arming inside the secured area, e.g. with control center Include a new area if not yet present. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 76 For reporting (Event Manager > Panel Event Groups > Properties > Reportable Events), set a Transmission Delay that is the same as the exit delay (typically 45 sec. / at least 30 sec.) for External Intrusion Alarm. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 77: Arming With Automatic Bypass

    Automatic disarming at a predefined time: defining the disarming time Start the schedule wizard and define the time of disarming. As action, select Disarm Area(s). See also – Arming with automatic bypass, page 77 Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 78: Alarm Output Via Siren And Communicator

    Internal warning device is activated for 3 sec. authorize from RPS with an AE 2 user with corresponding permissions (control center: main menu page 2 > RPS). Establish a connection between the panel and RPS. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 79 May perform software updates with RPS Operations category permissions May disable device May enable device May turn chime on/off May change schedule May edit blocking time User category permissions May add user May delete user Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 80 May print control panel history May view control panel version Maintenance category permissions May adjust control center volume/brightness May change output state May set date time May test bell May test motion detectors 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 81: Additional Functions Of The Main Panel

    Select EN50131 grade 3 as the default property values setting (refer to Standard- compliant programming, page 59). If the panel validation in accordance with EN 50131 grade 3 fails, do not proceed with programming the panel. Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 82: Automatic Arming / Disarming

    AE 3 Access for installers via control center or via RPS for MAP – AE 4 Access for manufacturers via RPS for MAP Level 2A is a subset of level 2B. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 83 Further subdivisions are possible within the access levels if the owner wishes to grant the users different permissions: User Manager > Permission Sets General permissions Access Level May silence buzzer on control center May change own user passcode Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 84 May disarm area Can disarm only if in alarm May bypass detectors May bypass detectors in area May unbypass detector May switch internal program on/off Status category permissions May view area status 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 85: Tamper Surveillance Of The Main Panel

    Design types of the communicators according to SES The transmission paths for remote alarm signaling are divided into the following: Bosch Sicherheitssysteme GmbH Installation manual 2016.06 | 17 | F.01U.168.332...
  • Page 86: Alarm Reporting

    For information security purposes, ICP-MAP5000-COM provides the possibility of encrypted transmission (AES 128, 192, 256). To grant anti-substitution security, the initial key has to be provided manually by typing it into the configuration software RPS for MAP. 2016.06 | 17 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 88 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2016...