Speaker
The Speaker Dialog offers the possibility to load the datasets of different loudspeaker systems, assign it to the
amplifier channels and display the acoustic results of this virtual combination. The speaker system datasets, which are
provided as "speaker files" (*.spk), contain factory-measured frequency- and phase responses of all common Electro-
Voice or DY- NACORD loudspeaker systems. Some examples are provided in the IRIS-Net directory Speaker Files.
HINT: When importing a speaker setting into a output channel the corresponding speaker file is imported
automatically.
The speaker data as well as any settings made in this window have no direct influence on the transfer function of the
amps. Nevertheless, they provide the user with the possibility for creating loudspeaker systems presets of a higher
quality. Overlaying the measured frequency- and phase responses in the equalizer and crossover windows enables the
user to customize the filter parameters. The summing display mode shows the result of amplifier plus speaker transfer
functions.
Clicking on the Speaker tab in the Setup & Control window opens the Speaker page.
Indication on the Graphic Display
Element
Channel Parameters
Element
Default
No
speaker
Bosch Security Systems B.V.
Description
Switch for toggling between frequency response (magnitude) and phase response
(phase) display
Switch for adjusting the scale of the amplifier axis to 25 dB (± 12.5 dB) or to 50 dB (± 25
dB)
Range
Description
The name of the loaded loudspeaker model is shown in the black-shaded
field.