Bosch IRIS-Net User Manual page 420

Table of Contents

Advertisement

IRIS-Net
Element
Default Range
6dB
1000Hz 20 Hz...20 kHz
1
Filter Editing via "Mouse Movement" in the Graphics Display
A white dot in the frequency response display represents an active filter (BYPASS not engaged). Clicking with the left
mouse button on this dot and keeping the mouse button pressed down allows changing the filter's frequency by
moving the mouse to the left or to the right. Clicking with the right mouse button on the white dot and keeping the
mouse button pressed down allows changing the Q-values (if SLOPE is set to 12dB) of the filter.
Bosch Security Systems B.V.
Description
Switches between frequency (magnitude)
and phase response (phase) indication.
Switch for selecting dB-axis scaling of 25 dB
(± 12.5 dB) or 50 dB (± 25 dB).
6dB, 12dB, 12dB
SLOPE sets the steepness or filter-order of
BS, 18 dB BS, 24
the high-pass filter..
dB BS (Bessel),
12dB BW, 18 dB
BW, 24 dB BW
(Butterworth), 12
dB LR, 24 dB LR
(Linkwitz-Riley)
FREQUENCY sets the cut-off frequency of the
high-pass filter.
0.4...100
The Q-value sets the quality and thus the
response of the high-pass filter with slope of
12dB/oct. This parameter is not available at
other slopes.
BYPASS switches the filter ON (not engaged)
or OFF (engaged), which allows for quick A /
B-evaluation of the actual effect that the
high-pass filter has on the sound.
User Manual
DIGITAL MATRIX | en
420
2017.05 | 3.20 | F.01U.119.956

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents