IRIS-Net
Element
Default
RAMP TIME
20 ms
RMS IN
10 ms
RMS DUGAN
10 ms
DIV DUGAN
10 ms
DIV FINAL
10 ms
BAND-PASS FILTER
A band-pass filter is a device that passes frequencies within a certain range and rejects frequencies
outside that range. The frequency and quality of the filter is adjustable.
Element
Default
1000Hz
1
Bosch Security Systems B.V.
Range
Description
1...20000 ms
Time constant of faders
1...2000 ms
Time constant of RMS measurement of input signals.
1...2000 ms
Time constant of RMS measurement of dugan-gain weighted input
signals.
1...2000 ms
Time constant for weighting rate of input signal level, based on total
level.
1...2000 ms
Time constant for rate of level change.
Range
Description
Switches between frequency (magnitude) and phase
response (phase) indication.
Switch for selecting dB-axis scaling of 25 dB (± 12.5
dB) or 50 dB (± 25 dB).
20
FREQUENCY sets the center frequency of the band-
Hz...20
pass filter.
kHz
0.4...1
The Q-value sets the quality and thus the response of
00
the band-pass filter.