Control Functions

Communication amongst amplifiers is possible through sending and receiving messages that are referred to as "job
codes". In principle, a job code is a function number. Amplifiers send these function numbers via the CAN bus. A single
or several amplifiers are able to receive and interpret these job codes and execute the associated functions. Each
amplifier can send and receive up to 5 different job codes.
The Control Functions Window lists the job code numbers that are used by all the amplifiers in a project like they were
defined in the amplifiers' Config & Info Window. When clicking on a number in the list of job code numbers in the left
part of the window, all amplifiers using this number are listed in the right part of the window. This, for example, allows
determination whether a specific job code number has been configured for all amplifiers in a project.
Setup & Control
The Setup & Control window allows configuring all amplifier parameters. It also provides access to different test
functions. The window is divided into several pages according to the corresponding function groups:
Window
Description
Config & Info
This page provides information about the amplifier and allows making several basic settings as well
as programming control functions.
DSP
The DSP page provides an overview plus access to all DSP functions (Filter, Delay, X-Over,
Dynamics) of the amplifier.
Speaker
This page allows loading and displaying speaker data.