IRIS-Net
Open the "Topology / Zones" dialog and add a non-DPA amplifier, select the DPM Audio output to be used for the
PM4000. Connect the non-DPA amplifier with the PM4000 topology. Go back to "Interfaces" dialog and check correct
DPM8016 audio output (comboBox "AUDIO OUTPUT"). Choose an audio input at the PM4000 (selection field "AUDIO
INPUT"). Please ensure that the PM 4000 system offers a free input (re-programming may be necessary).
For fault indication (fault interface), a Memo Flag can be programmed in the PM 4000 system which is triggered via the
PM 8000 by setting the "MEMOFLAG BROKEN LINE" selection field accordingly.
If the PM 4000 time shall be used as system time, the PM 8000 system can act as time slave. In this case, at the DPM
8016 dialog "General", the time synchronization has to be set to "DPM 4000 synchronisation".
Power Management dialog
The Power Management dialog allows configuring the standby mode of the DPM 8016 in detail.
Element
POWER ON/OFF SIGNAL
EXTERNAL ON/STANDBY
Bosch Security Systems B.V.
Description
Select the GPO contact or the virtual TE value for signaling the DPM
operating mode. In standby mode the GPO is open.
Select the digital GPI or virtual TE value to be used for switching to
standby mode.