MAP 5000
ICP‑MAP5000‑2 / ICP‑MAP5000‑COM / ICP‑MAP5000‑S /
ICP‑MAP5000‑SC
en
Installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch MAP 5000

  • Page 1 MAP 5000 ICP‑MAP5000‑2 / ICP‑MAP5000‑COM / ICP‑MAP5000‑S / ICP‑MAP5000‑SC Installation manual...
  • Page 3: Table Of Contents

    MAP 5000 Table of contents | en Table of contents Introduction Short information Listings and approvals Battery handling Installation considerations Planning the system 1.5.1 Planning the system with IPP-MAP0005 power supply 1.5.2 Planning the system with ICP-MAP0012 CAN splitter module...
  • Page 4 | Table of contents MAP 5000 4.3.3 Manufacturer authorization Completing the installation Point types and point evaluation Output functions 4.6.1 Programmable output signals 4.6.2 Sirens and communicator in accordance with EN50131 grade 3 Enclosure options ICP-MAP0115 power enclosure Rack mount option for ICP-MAP0120 expansion enclosure...
  • Page 5: Introduction

    Short information This manual describes the installation, wiring, initial set-up and maintenance of the MAP 5000 system. It is applicable for all MAP 5000 kits and the following main panels including all accessory MAP 5000 products: – MAP Main Panel (ICP-MAP5000-2) –...
  • Page 6: Planning The System

    | Introduction MAP 5000 – Follow anti-static procedures when handling system components. Ensure that you are properly grounded to discharge any static charge before you work with system components. – Install all components in dry, maintained interior rooms. –...
  • Page 7: Planning The System With Ipp-Map0005 Power Supply

    MAP 5000 Introduction | en This module mounts on the ICP-MAP0025 hinged mounting plate. This module mounts on the ICP-MAP0020 accessory mounting plate, which mounts to the back of the enclosure. When determining the number of power supplies, it is also necessary to take into account the inrush current of loads (refer to Planning the system with IPP-MAP0005 power supply, page This assembly is only required if the IPP-MAP0005 power supply is installed.
  • Page 8 | Introduction MAP 5000 Condition 1 3-wire cables are always used for connections between power supply segments (without +28 V, red wire) Figure 1.1: Wiring of power supply segments Condition 2 Charged batteries must be connected to the power supply to ensure reliable system start-up.
  • Page 9 MAP 5000 Introduction | en ICP-MAP0111 Figure 1.3: Wiring with ICP-MAP0111 Description Current limitation 4-wire connection, take into account cable length 3-wire connection to the next power supply segment Short-time current limitation to 3.2 A per output A / B Current limitation to 1.6 A between internal and external BDB Remote operation with ICP-MAP0120 expansion enclosure Figure 1.4: 2 LSN modules with up to 4 control centers...
  • Page 10 | Introduction MAP 5000 Figure 1.5: Up to 8 control centers Description Current limitation 4-wire connection, take into account cable length, refer to , page 10 3-wire connection to the next power supply segment Short-time current limitation to 3.2 A per output A / B...
  • Page 11: Planning The System With Icp-Map0012 Can Splitter Module

    MAP 5000 Introduction | en 1.5.2 Planning the system with ICP-MAP0012 CAN splitter module When using a CAN splitter module to split the external BDB into two independent areas, chose one of the following wiring possibilities: Wiring with a CAN splitter module and a MAP LSN gateway module...
  • Page 12: System Overview

    | Introduction MAP 5000 Relation of cable length, diameter and number of keypads Cable Number of keypads diameter 0.6 mm 225 m 225 m 200 m 150 m 120 m 100 m 0.8 mm 400 m 400 m 350 m...
  • Page 13 MAP 5000 Introduction | en System installation in ICP-MAP0111 panel enclosure (hinged mounting plate open) ICP-MAP0111 System installation in ICP-MAP0120 expansion enclosure Bosch Sicherheitssysteme GmbH Installation manual 2018.08 | 23 | F.01U.168.332...
  • Page 14 | Introduction MAP 5000 Enclosure overview ICP-MAP0111 Element Description Wire trays Wire knockouts Mounting rails for ICP-MAP0020 accessory mounting plate Mounting location for TAE box Knockout for wall tamper Mounting location for ICP-MAP0065 AC terminal block Earth ground connection points...
  • Page 15: Installation

    MAP 5000 Installation | en Installation – Use proper anchor and screw sets when installing the enclosure on surfaces. Refer to the drill template for detailed instructions. – Ensure that there is enough free space to the left of the enclosure so that the enclosure door and the ICP-MAP0025 hinged mounting plate have full range of motion.
  • Page 16: Installing The Tamper Switch Rail

    | Installation MAP 5000 Knockout for AC wires (use when AC wires come in from the back of the enclosure) Side wall knockouts for wiring Installing the tamper switch rail Remove the tamper switch rail from the package. Mount the tamper switch rail to the inner right side of the enclosure as shown in the figure below.
  • Page 17: Mounting The Enclosure

    MAP 5000 Installation | en Mounting the enclosure Notice! Ensure that there is enough free space to the left of the enclosure so that the enclosure door and the ICP-MAP0025 hinged mounting plate have full range of motion. - For a fully opened door, at least 460 mm (18 in) is required.
  • Page 18 | Installation MAP 5000 Mounting the enclosure ICP-MAP0111 Element Description Mounting hole Hole for screw to secure wall tamper plug Mounting an edge protection profile (optional) For an installation according to the regulations of NFa2p AFNOR certification, it is necessary to mount an edge protection profile on the upper edge of the MAP enclosure.
  • Page 19: Checking The Ac Connection

    MAP 5000 Installation | en Mounting an edge protection profile Element Description cut-outs edge protection profile Checking the AC connection Ensure that the AC circuit breaker switch is off. Connect the AC line to the AC terminal block. Switch the AC breaker on.
  • Page 20 | Installation MAP 5000 Installing the power supply ICP-MAP0111 IPP-MAP0005 IPP-MAP0005 power supply ratings label Put the power supply ratings label on the side of the power supply as shown in the picture below. 2018.08 | 23 | F.01U.168.332...
  • Page 21 MAP 5000 Installation | en IPP-MAP0005 power supply warning label The power supply warning label needs to be put on the enclosure back wall before installing the AC terminal block. The power supply warning label indicates that the terminal block connected to the AC terminal block may never be removed from the power supply during operation.
  • Page 22 | Installation MAP 5000 Figure 2.2: Putting the power supply warning label into the ICP-MAP0120 enclosure Refer to Technical Specifications, page 68 for power specifications. Installing the AC terminal block Mount the AC terminal block to the enclosure back wall into the corresponding mounting holes as shown in the figure below and secure it with the supplied screws (1).
  • Page 23: Installing The Tae Box

    MAP 5000 Installation | en Warning! When installing the power supply, ensure that the ground wire from the AC terminal block is connected to the ground connection point as shown in , page 22. The ground wire from the AC terminal block to the power supply does not provide an earth ground for the enclosure.
  • Page 24: Installing The Accessory Mounting Plate

    | Installation MAP 5000 Installing the TAE box ICP-MAP0111 Installing the accessory mounting plate Align the earth ground stud on the accessory mounting plate with the earth ground hole on the top mounting rail in the upper right side of the enclosure wall as shown in the figure below.
  • Page 25 MAP 5000 Installation | en Aligning the accessory mounting plate ICP-MAP0111 ICP-MAP0020 Ensure that the locking clips snap into the bottom mounting rail as shown in the figure below. Installing the accessory mounting plate Refer to Accessory mounting plate overview, page 26 for the locations of the modules that mount on the accessory mounting plate.
  • Page 26: Installing The 12 V Converter

    | Installation MAP 5000 Accessory mounting plate overview ICP-MAP0111 Element Description Locations for ICP-MAP0017 12 V converters (two maximum) Location for fuse plate (SIV) (one maximum) Screw locations for AT 2000 communicator (one maximum) Screw location for AT 2000 earth ground...
  • Page 27: Installing The Fuse Plate (Siv)

    MAP 5000 Installation | en Installing the 12 V converter Installing the fuse plate (SIV) Mount the fuse plate (SIV) onto the accessory mounting plate as shown in the figure below (screws not supplied). Connect the field wiring to the terminal block of the fuse plate (SIV) as shown in the figure below and leave the other ends unconnected.
  • Page 28: Installing The At 2000 Communicator

    | Installation MAP 5000 Installing the SIV 2.10 Installing the AT 2000 communicator The AT 2000 communicator mounts onto the ICP-MAP0020 accessory mounting plate over the 12 V converter (if installed). If the fuse plate (SIV) is mounted on the accessory mounting plate, the communicator cannot be mounted on the same mounting plate.
  • Page 29 MAP 5000 Installation | en Installing the AT 2000 communicator Connect the AT 2000 communicator to the ICP-MAP0007 DE module using the supplied ribbon cable (P/N F01U074773). The cable is supplied with the DE module. The ribbon cable is used for all connections of the communicator input lines and for the "Communicator Trouble"...
  • Page 30 | Installation MAP 5000 Analog AT 2000 to DE module connections Notice! The two trouble inputs are automatically configured to "Communicator Trouble" and "Negative Acknowledgment" when "Communicator" is selected in the Remote Programming Software (RPS). 2018.08 | 23 | F.01U.168.332...
  • Page 31 MAP 5000 Installation | en Analog AT 2000 to ICP-MAP0017 12 V converter connections Bosch Sicherheitssysteme GmbH Installation manual 2018.08 | 23 | F.01U.168.332...
  • Page 32 | Installation MAP 5000 AT 2000 ISDN to DE module connections 2018.08 | 23 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 33: Installing The Hinged Mounting Plate

    MAP 5000 Installation | en 2.11 Installing the hinged mounting plate Install the ICP-MAP0025 hinged mounting plate inside the enclosure ICP-MAP0111 or ICP- MAP0120. Installing the hinged mounting plate ICP-MAP0111 ICP-MAP0025 Mounting modules onto the hinged mounting plate The following graphic shows an overview of the hinged mounting plate and the designated mounting locations of the modules.
  • Page 34 | Installation MAP 5000 Hinged mounting plate overview ICP-MAP0007 ICP-MAP5000 ICP-MAP0025 ICP-MAP0010 ICP-MAP0012 Slide the module onto the hinged mounting plate. Ensure that the locking clips snap into a pair of rectangular openings on the bottom rail. 2018.08 | 23 | F.01U.168.332...
  • Page 35 MAP 5000 Installation | en Sliding the module onto the hinged mounting plate Connect the grounding cable from the enclosure back wall to the hinged mounting plate. Bosch Sicherheitssysteme GmbH Installation manual 2018.08 | 23 | F.01U.168.332...
  • Page 36: Mounting The Main Panel

    | Installation MAP 5000 Connecting the grounding cable to the hinged mounting plate 2.12 Mounting the main panel This chapter describes the mounting of the following main panels: – MAP Main Panel (ICP-MAP5000-2) – MAP Main Panel with IP Communicator (ICP-MAP5000-COM) including the MAP GSM module (ITS-MAP0008).
  • Page 37: Installing The Icp-Com-If Relay Module

    MAP 5000 Installation | en Position the ferrite core as close as possible to the enclosure knockout inside the enclosure. Ferrite core 2.13 Installing the ICP-COM-IF relay module The ICP-COM-IF relay module can be mounted on the hinged mounting plate or the mounting rails of the MAP control panel enclosure.
  • Page 38: Installing And Connecting The Its-Map0008 Wireless Modem

    | Installation MAP 5000 Installing the ICP-COM-IF relay module 2.14 Installing and connecting the ITS-MAP0008 wireless modem The ITS-MAP0008 wireless modem is used for wireless transmission of data via GSM/GPRS. The ITS-MAP0008 wireless modem can only be used when one of the following main panels is installed: –...
  • Page 39 MAP 5000 Installation | en Warning! In order to avoid data loss on the SIM card, the wireless modem must be de-energized before inserting or removing the SIM card. Installing and connecting the ITS-MAP0008 wireless modem ITS-MAP0008 ICP-MAP0152 LED operating status...
  • Page 40: Antennas

    | Installation MAP 5000 LED mode Operating status of M terminal 75 ms on, 75 ms off, 75 ms One or more GPRS contexts activated. on, 3 s off 500 ms on, 25 ms off Packet switched data transfer in progress.
  • Page 41: Connections

    MAP 5000 Connections | en Connections Caution! Wiring Pinching of the wires is possible due to incorrectly hinged components. – Ensure that there is sufficient slack in the service wire loop to allow proper movement of the hinged mounting plates.
  • Page 42 | Connections MAP 5000 Data bus connections of the system modules on the internal BDB Notice! The order of system modules on the BDB shown in the figure is not mandatory. A symmetrical load distribution to the power supply outputs A and B must be ensured as far as possible.
  • Page 43: Internal / External Data Bus

    Connections | en 3.1.1 Internal / external data bus The MAP 5000 system contains two data buses (BDB), which are used to connect the system modules to the main panel. Internal BDB The maximum length of the internal BDB is 3 m.
  • Page 44: Splitting The External Data Bus With A Can Splitter Module

    | Connections MAP 5000 Bus wiring without consideration of the power supply = 120 Ohm Max. 1000m 3.1.3 Splitting the external data bus with a CAN splitter module The external BDB can be splitted into two independent and isolated stubs to connect keypads, gateways and further power supplies.
  • Page 45: Connecting The Main Panel

    MAP 5000 Connections | en Data bus connection of the control center on the external BDB Connecting the main panel This chapter describes the connection of the following main panels: – MAP Main Panel (ICP-MAP5000-2) – MAP Main Panel with IP Communicator (ICP-MAP5000-COM) including the MAP GSM module (ITS-MAP0008).
  • Page 46: Connecting The Power Supply

    | Connections MAP 5000 External BDB connector (1) Use this connection to connect additional system modules to the external BDB (refer to Connecting the data bus, page 41 and Modules on the BDB, page 43). Programmable voltage outputs (2) Use these connections to control devices in certain system states (refer to Programmable output signals, page 60).
  • Page 47: Connecting The Lsn Gateway

    MAP 5000 Connections | en Battery circuit 2 Battery circuit 1 Connection for thermistor Power connection to main panel Input for tamper switch, is activated by configuration for remote operation of the power supply on the external BDB. Output for voltage supply (switched), supervised, nominal voltage 24 V DC...
  • Page 48 | Connections MAP 5000 LSN gateway loop configuration ICP-MAP0111 2018.08 | 23 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 49: Optional Connections

    MAP 5000 Connections | en LSN gateway stub configuration ICP-MAP0111 Optional connections Optional power supply connections Connect the auxiliary DC power for the 12 V converter. Connect the supervision outputs. The supervision outputs monitor AC mains failure and summary power supply trouble.
  • Page 50 | Connections MAP 5000 Connecting the power supply Optional DE module connections If a DR2020 printer is used, connect the DE module to the DR2020. Connect the supervised sirens and strobes to the DE module outputs. 2018.08 | 23 | F.01U.168.332...
  • Page 51: Installing And Connecting The Tamper Switch

    MAP 5000 Connections | en Connecting the DE module Installing and connecting the tamper switch – Install the ICP-MAP0050 control panel enclosure tamper switch in the ICP-MAP0111 panel enclosure. – Install the ICP-MAP0055 expansion enclosure tamper switch in the ICP-MAP0120 expansion enclosure.
  • Page 52 | Connections MAP 5000 Tamper switch extension piece Slide the tamper switch onto the rail as shown in the figure below. Mounting the tamper switch onto the rail Clip off the connector from the cable of the tamper switch.
  • Page 53: Installing The Icp-Map0060 Enclosure Lockset

    MAP 5000 Connections | en Connecting the ICP-MAP0050 tamper switch ICP-MAP5000 ICP-MAP0050 Connecting the ICP-MAP0055 tamper switch ICP-MAP0055 IPP-MAP0005 Notice! When the enclosure door is opened, the tamper switch creates a tamper condition. To allow for a local connection between RPS and the ICP-MAP5000 panel, connect the tamper switch to the panel and not the power supply.
  • Page 54 | Connections MAP 5000 Installing the enclosure lockset Connect the long grounding cable (P/N F01U074762) to the enclosure door. Connecting the grounding cable to the enclosure door 2018.08 | 23 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 55: Installing The Control Center

    MAP 5000 Connections | en Installing the control center Mounting location Mount the control center onto the wall so that the user interface is at a comfortable level for the end user. Typical installations of the touchscreen are at shoulder level, which is approximately 150 to 160 cm (59 to 62 in) above the floor.
  • Page 56: Ip Interface

    Ethernet- connector RJ 45 Ethernet cable type: CAT5e VdS and EN50131: The usage of the MAP 5000 Ethernet interface is permitted if the following conditions are met. Use a direct connection (1:1 connection) for connecting the management system to MAP5000.
  • Page 57: Initial Set-Up And Programming

    MAP 5000 Initial set-up and programming | en Initial set-up and programming Initial set-up First check the following before initial set-up: – Are all cables connected correctly? – The power supply is always in operation after the AC mains has been connected and the AC breaker switched on.
  • Page 58: Help For The Programming Software

    Click on the yellow RPS button and create a new panel account with the New button. In the Hardware Manager, click on the MAP 5000 Panel node and then in the Properties field on the parameter Default Property Values Set and select the standard that you want to program.
  • Page 59: Software Updates

    MAP 5000 Initial set-up and programming | en Make a connection to the panel. Click on the MAP 5000 Panel node. The software version is displayed in the Properties field under Control Panel Firmware Version. Click successively on the system modules in the Hardware Manager.
  • Page 60: Output Functions

    | Initial set-up and programming MAP 5000 Trouble Technical Fire Assignment to Internal Program not possible or with no effect Output functions 4.6.1 Programmable output signals The following functions can be programmed at outputs. p = programmable Behavior item type Output is activated for …...
  • Page 61 MAP 5000 Initial set-up and programming | en Report failure summary alarm Panel has received negative acknowledgment from communicator due to report failure summary alarm Report failure summary trouble Panel has received negative acknowledgment from communicator due to report failure trouble...
  • Page 62: Sirens And Communicator In Accordance With En50131 Grade 3

    | Initial set-up and programming MAP 5000 Reportable external intrusion Reporting of external intrusion alarm event, possibly also alarm delayed if present/absent option is used Reportable external tamper Reporting of external tamper alarm event, possibly also alarm delayed if present/absent option is used...
  • Page 63 MAP 5000 Initial set-up and programming | en – One communicator (class 4) Connections R1 – R7 on ICP-COM-IF Variant B (ICP-COM-IF required) – One self-powered siren Outputs 10 / 11 or 13 / 14 on ICP-MAP5000 main panel –...
  • Page 64: Enclosure Options

    | Enclosure options MAP 5000 Enclosure options ICP-MAP0115 power enclosure ICP-MAP0115 power enclosure connections ICP-MAP0111 ICP-MAP0130 IPP-MAP0005 ICP-MAP0065 P/N: F0U124597 ICP-MAP0115 ICP-MAP0130 P/N: F0U124597 ICP-MAP0050 BAT1 ICP-MAP0065 BAT2 IPP-MAP0005 Connect the ICP-MAP0115 power enclosure to the ICP-MAP0111 enclosure to provide additional power when high power capacity is required.
  • Page 65: Rack Mount Option For Icp-Map0120 Expansion Enclosure

    MAP 5000 Enclosure options | en Rack mount option for ICP-MAP0120 expansion enclosure To install the ICP-MAP0120 expansion enclosure in a 19-inch rack, connect the ICP- MAP0035 rack mount brackets to the ICP-MAP0120 expansion enclosure. Installing the rack mount brackets to the ICP-MAP0120 expansion enclosure...
  • Page 66: Maintenance And Service

    Notice! Have maintenance and inspection work carried out regularly by trained expert personnel. Bosch Sicherheitssysteme GmbH recommends performing a functional and visual inspection at least once annually. Danger! Danger of electric shock if live parts are touched. For your safety, you should switch off the...
  • Page 67 MAP 5000 Maintenance and service | en The initialization phase, indicated by a blinking LED, starts. The LEDs on the main panel and all other installed modules start indicating and the system is ready for operation again. LED status Description...
  • Page 68: Technical Specifications

    | Technical Specifications MAP 5000 Technical Specifications Electrical Maximum operating voltage in VAC 230 (-15 %, + 10%) Minimum AC line frequency in Hz Maximum AC line frequency in Hz Maximum power consumption in W per power supply Minimum battery capacity in Ah per power...
  • Page 69 1, RJ 45 connection Management system connection Via Ethernet interface and the Open Intrusion Interface OII or the MAP OPC server from Bosch - in VdS systems, only feedback-free connection as information system via exclusive transmission path Number of inputs...
  • Page 70 | Technical Specifications MAP 5000 Maximum relative humidity in % Protection class IP30 IP31 (with an edge protection profile) Security level IK06 Environmental class EN60950-1, EN50130-4, EN50131-1, VdS 2110 Usage Indoor 2018.08 | 23 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 71: Appendices

    MAP 5000 Appendices | en Appendices This chapter contains information and instructions for creating programming that complies with the requirements of a specific standard. Notice! Use the default setting for parameters that are not explicitly mentioned in this description. In addition, the instructions for panel validation in the RPS for MAP programming software must be followed.
  • Page 72 | Appendices MAP 5000 Open control panel enclosure. authorize from RPS with an AE 2 user with corresponding permissions (control center: main menu page 2 > RPS). Establish a connection between the panel and RPS. AE 4 Access for manufacturers via RPS for MAP Authorize the manufacturer user with an AE 2 user with corresponding permissions (control center: main menu page 1 >...
  • Page 73 MAP 5000 Appendices | en May clear tamper May clear trouble May clear battery trouble May silence Remote service category permissions May authorize manufacturer user May authorize RPS user Arm category permissions May arm area May disarm area Can disarm only if in alarm...
  • Page 74: Requirements In Accordance With En 50131 Grade 3

    | Appendices MAP 5000 Requirements in accordance with EN 50131 grade 3 Notice! If not all requirements in accordance with this standard can be satisfied or only a lower grade can be met, the compliance mark (EN 50131 grade 3) must be either removed or adapted.
  • Page 75 MAP 5000 Appendices | en Include a control center if not yet present. Include the area in the scope of the control center: Local Area. Program control center for arming with exit delay: Use Area Normal Delay Time. The value for the entry / exit delay can be adapted if required: Area Manager > Area >...
  • Page 76: Arming With Automatic Bypass

    | Appendices MAP 5000 8.2.5 Arming with automatic bypass Points that are not in normal state and therefore prevent arming can be automatically bypassed for arming. These points are automatically unbypassed again when the system is next disarmed. Program point to point type Intrusion (Bypassable) or Intrusion 24h (Bypassable).
  • Page 77: Alarm Output Via Siren And Communicator

    MAP 5000 Appendices | en 8.2.7 Alarm output via siren and communicator Alarms, trouble events and other events must be output via siren and/or communicator. For possible variants, refer to Sirens and communicator in accordance with EN50131 grade 3, page 62.
  • Page 78 | Appendices MAP 5000 AE 4 Access for manufacturers via RPS for MAP Authorize the manufacturer user with an AE 2 user with corresponding permissions (control center: main menu page 1 > maintenance page 3 > manufacturer permission). Open control panel enclosure.
  • Page 79 MAP 5000 Appendices | en May change user passcode Event category permissions May clear internal alarm May clear external alarm May clear tamper May clear trouble May clear battery trouble May silence Remote service category permissions May authorize manufacturer user...
  • Page 80: Additional Functions Of The Main Panel

    | Appendices MAP 5000 May walk test automatic points May walk test points Tab. 8.5: Permissions See also – Installer button, page 66 – Manufacturer authorization, page 59 8.2.11 Additional functions of the main panel The panel has the following additional functions which do not have any influence on the intended operation of the panel.
  • Page 81: Automatic Arming / Disarming

    MAP 5000 Appendices | en See also – Point types and point evaluation, page 59 – Standard-compliant programming, page 58 8.3.2 Automatic arming / disarming Arming without a warning signal is permitted if it is possible to ensure by technical or organizational measures that there are no persons in the supervised area before arming.
  • Page 82 | Appendices MAP 5000 Selecting the access level AE 1 Access for everyone, no authorization/code required AE 2A Access for users, user passcode required AE 2B Access for users, user passcode required AE 3 Access for installers via control center Open control panel enclosure.
  • Page 83 MAP 5000 Appendices | en May transmit/receive programming with RPS May receive history with RPS May perform diagnostics with RPS May perform software updates with RPS Operations category permissions May disable device May enable device May turn chime on/off May change schedule...
  • Page 84: Tamper Surveillance Of The Main Panel

    | Appendices MAP 5000 May view device status May view duress alarm May view alarm count May view event memory May view control panel history May print control panel history May view control panel version Maintenance category permissions May adjust control center volume/brightness...
  • Page 85: Alarm Reporting

    SIA DC 09 – VDS 2465 Transmission path faults are directly reported to the user via the MAP 5000 control center. ICP-MAP5000-COM and ICP-MAP5000-SC have implemented layer 1 supervision for Ethernet and wireless path. ICP-MAP5000-COM and ICP-MAP5000-SC supervise the link to Ethernet and poll the wireless network on checking for connection, signal strength and sign in status.
  • Page 86: History Log

    RPS for MAP. History log The history log of the MAP 5000 panel can be configured for 1000 to 4000 entries using RPS for MAP 5000. For the SPT functionality, an additional history log of 1000 entries is available.
  • Page 88 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2018...