Bosch IRIS-Net User Manual page 465

Table of Contents

Advertisement

IRIS-Net
Commands for Compressor
/
/DSP
/
PARA
COMPRESS
M
OR_x
Commands for Delay
/
/DSP
/
PARA
DELA
M
Y_x
Bosch Security Systems B.V.
/ATTACK
/
VALU
E
/BYPASS
/
VALU
E
/
/
GAINREDU
VALU
CTION
E
/
/
MAKE_UP_G
VALU
AIN
E
/RATIO
/
VALU
E
/RELEASE
/
VALU
E
/SOFTKNEE /
VALU
E
/
/
THRESHOL
VALU
D
E
/BYPASS
/VALUE
Read
Write
Values
R / W
5...150
R / W
0, 1
R
R / W
-18...6
R / W
1...100
R / W
10...1000
R / W
0...20
R / W
-9...21
Read
Write
Values
R / W
0, 1
User Manual
DIGITAL MATRIX | en
Description
Attack time in ms
0 = Bypass not activated, 1 =
Bypass activated
Gain reduction as full scale value
(32 bit) Transform given value
into dB by: 20 log (0x7FFFFF/
value)
Gain of compressor output in
dB, not available for RCM24
compressor
Compressor ratio
Release time in ms
Soft knee in dB, not available for
RCM24 compressor
Threshold in dB
Description
0 = Bypass not activated, 1 =
Bypass activated
2017.05 | 3.20 | F.01U.119.956
465