IRIS-Net
Element
TYPE
CONDITION
INVERT
START/ADD TRIGGER
STOP/SUB TRIGGER
PAGING
Bosch Security Systems B.V.
Description
A paging can be either of type PULSE or of type STATIC. By default a paging is of
type STATIC.
The status of the condition selected here starts the paging, e.g. the contact of a
CIE connected to a GPI of the device. As further option, virtual paging conditions
can be selected that, for example, can be directly linked to call a station key
(normal key or supervised Alarm Button). By default, 10 virtual paging conditions
are available. If more are required, the property Pagings.VCondition.NrOf may
be changed.
Set the checkbox to invert the condition that starts the paging.
The value used to trigger the start of (or addition of destinations to) an active
paging. The rising edge of the value is evaluated.
The value used to trigger the stop of (or subtraction of destinations from) an
active paging. The rising edge of the value is evaluated.
The paging initiated by the condition.