Output Programming; Output Commands; Output Status - Bosch Solution 16plus Installation Manual

Hide thumbs Also See for Solution 16plus:
Table of Contents

Advertisement

T
he Solution 16
is capable of controlling up to 8 outputs.
plus
The first 4 outputs are on the main control board and an
additional 4 outputs are provided using an output expander
module. Each output can have its own unique name up to 16
characters to identify it on the system for display and reporting
purposes.
Under the commands menu you are able to view the status of
any output and to change its on/off condition. In the case of
latching output types, you will be required to reset the output
manually using these commands.
Outputs are programmed using an event type. First select the
event type that will cause the output to trigger. Then select the
polarity of the event, if it is low and goes high or high and goes
low. If the event is pulsing or one shot type, the time parameter
must also be programmed to define the time of the pulse.
Event Assignment, this is extremely important parameter and
has a different meaning depending on the event type selected.
For example, event type "24 - Area Part On" the event assignment
selects the Area that is armed in part on for the output to trigger.
If you set the event assignment to 1, then it will correspond to
area 1 and so on, setting it to zero means all areas. See the event
type table for more detail on the relationship of event type to
event assignment.
Outputs 1 and 2 are special outputs that can be configured as
horn speaker polarity types and are monitored to report a device
connection trouble. Output 4 is a dry relay contact which has a
optional jumper that allows you to switch positive or negative
without the need to add additional wiring.
The outputs are all protected and will shut down individually
under overload conditions. A report will be generated and a
displayed on the keypad to indicate the trouble condition.
Bosch Security Systems 05/10 BLCC100I

Output Programming

OU TPU T COMMA ND S
Outputs > Commands >

Output Status

This command allows you to view the current status of any
system output.
1)
Press [MENU] + [4] + [0] + [0] and select the output you want to
view from the list then press [OK]. Alternatively, you can
directly enter the output number that you want to view then
press [OK].
The keypad will display the following when the output is
2)
currently in the OFF state and ready to activate.
Output 1 Name Op001
Is OFF and Ready
Press OK or MENU
3)
The keypad will display the following when the output is
currently in the OFF state but the connection is missing.
Output 1 Name Op001
Is OFF and Ready
Connection Trouble
Press OK or MENU
4)
The keypad will display the following when the output is
currently in the ON state and ready.
Output 1 Name Op001
Is ON and Timing
Triggered
Press OK or MENU
5)
The keypad will display the following when the output is
currently in the ON state but the connection is missing.
Output 1 Name Op001
Is ON and Timing
Connection Trouble
Press OK or MENU
Press [OK] or [MENU] to exit.
6)
SECT ION 8
-
-
-
MENU 4-0-0
8-1