O u t put Ar ray
This feature allows you to view output status in groups of
16. From the installer programing mode press MENU 4-0-2
to access the output array.
Use the up and down arrow keys to scroll up and down the
output banks and press [OK] or [MENU] when finished.
The following information can be displayed depending on
the current zone status.
N = NORMAL - Off Condition
T = TRIGGERED - On Condition
F = FAULT - Overload Condition
- = DISABLED
1. Enter [MENU] + [4] + [0] + [2] and use the up and
down arrows to select the output group to view.
2. Use the [] and [] down arrows at any time to move
to a new group. The keypad will display the following
output array information for outputs 1 to 16.
0000000001111111
1234567890123456
NNNNN---TF------
Press  OK or MENU
In the above example screen,
N = Outputs 01 to 05 are Normal (Off )
F = Output 10 has a Fault (Overload)
T = Output 09 is Triggered (On)
- = Outputs 05 to 08 and Outputs 11 to 16 are
Disabled or Not Available
B a s i c Rep o r ti n g R e fe re nce
A complete reporting template is available on the Solution
Link CD or from your nearest Bosch security products outlet.
Your base station will need to create a specific reporting
template for this and other new model Solution panels.
Point ID Table
Ur999
Ur998
Ur997
Ur996
Ur001 - 995
Ur000
Zn001 - 264
Zn001 - 064
Zn701 - 708
Zn711 - 718
Zn761 - 768
Zn771 - 778
Zn781 - 788
Zn791 - 798
Bosch Security Systems 10/22 BLCC615R
Module Description
Installer
Remote User
TimeZone
Guard Tour
Users
Quick Arm
Zones General
Doors 1 - 64
Door Controller 1 - 8
Door Controller 9 - 16
Lift Controller 1 - 8
Lift Controller 9 - 16
Input Expander 1 - 8
Input Expander 9 - 16
Solution 6000-IP Quick Start Guide
Zn801 - 808
Universal Expander 1 - 8
Zn811 - 818
Universal Expander 9 - 16
Zn821 - 828
RF Receiver 1 - 8
Zn831 - 838
LAN Power Supply 1 - 8
Zn841 - 848
Serial Expander 1 - 8
Zn851 - 858
Output Expander 1 - 8
Zn860
GSM Module
Zn861
GSM Input 1
Zn862
GSM Input 2
Zn863
GSM Input 3
Zn864
GSM Input 4
Zn870
Ethernet Module
Zn871
Real Time Clock Module
Zn873
Service Keypad
Zn881 - 888
Consoles 1 - 8
Zn891 - 898
Control Panel 1 - 8
Zn911 - 918
LAN Isolator 1 - 8
Zn921 - 928
LAN Isolator 9 - 16
Zn901 - 908
Destination Route 1 - 8
Zn971 - 978
Consoles 9 - 16
Zn901 - 908
Destination Route 1 - 8
Zn911 - 918
LAN Isolator 1 - 8
Zn921 - 928
LAN Isolator 9 - 16
Zn931 - 938
LAN Power Supply 9 - 16
Zn951 - 958
Output Expander 9 - 16
Zn971 - 978
Consoles 9 - 16

Table 13: Shortform Point ID List