Directory Information Display - Yamaha RCX40 User Manual

4-axis robot controller
Table of Contents

Advertisement

n
NOTE
The following program names have
special meanings.
"FUNCTION"
"SEQUENCE"
"_SELECT"
"COMMON"
(Refer to "Programming Manual" for
these programs.)
n
NOTE
Program names can be up to 8
characters consisting of a combination
of alphanumeric characters (0 to 9, A
to Z) and underscores ( _ ).
Fig. 4-10-19 Registering a new program
PROGRAM
>DIR
No.
NAME
1
TEST1
2 *TEST2
3
PARTS100
4
TEST100
Enter program name >ABC123_
3) Press the
key to register the program name.
10.3.3

Directory information display

[Procedure]
In "PROGRAM>DIR" mode, press the
"PROGRAM>DIR>INFO" mode. The following information on the selected program
appears.
Fig. 4-10-20 Program information
PROGRAM
>DIR>INFO
Source(use/sum)
Object(use/sum)
Sequence(use/sum)
Number of program
Number of points
Item
Source (use/sum)
Displays the byte counts used and available for source program and point data.
Object (use/sum)
Displays the byte counts used and available for object program.
Sequence
Displays the byte counts used and available for sequence object program. (8 bytes are
(use/sum)
used for one circuit of sequence program.)
Number of program
Displays the number of programs.
Displays the number of points that have been set. (28 bytes are used for one point.)
Number of points
10. "PROGRAM" mode
<TEST1
LINE
BYTE
RW/RO
55
952
RW
50
907
RW
38
843
RW
100
1968
RW
(INFO) key to enter
F 5
<TEST1
=
1316/196608 bytes
=
528/ 98304 bytes
=
0/
4096 bytes
=
5
=
124
Description
>
4
>
59
4-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents