12.1.4.1 Option DIO setting

The following parameter for option DIO (NPN or PNP specifications) boards is used to
enable or disable monitoring of the DC 24V supply input.
Parameter
1.
Board status
[Procedure]
Fig. 4-12-41
SYSTEM>PARAM>OP.BRD
1.D_Net
2.DIO_N(1)
3. ---
4. ---
SELECT
1) In "SYSTEM>PARAM>OP. BRD" mode, select the option DIO board with the
cursor keys and press the
Fig. 4-12-42
SYSTEM>PARAM>OP.BRD>SELECT
1.Board condition
EDIT
JUMP
2) Press the
(EDIT) key.
F 1
Fig. 4-12-43
SYSTEM>PARAM>OP.BRD>SELECT
1.Board condition
INVALID
VALID
3) Press the
(INVALID) or
F 1
the DC 24V supply input.
4) Press the
key to quit the edit mode.
ESC
12. "SYSTEM" mode
Meaning
Enables or disables monitoring of the 24V supply input. When set
to "VALID", an error message will be issued as a warning and
recorded in the error history if the DC 24V supply is shut off.
When set to "INVALID", no error message will be issued and
recorded in the error history even if the DC 24V supply is shut off.
(SELECT) key.
F 1
(VALID) key to select whether to monitor
F 2
V8.18
VALID
VALID
V8.18
VALID
V8.18
VALID
175
4-
4