Connecting Cables And The Line Network; Figure 4-111 Hipath 3500 And Hipath 3300 - Connection Cable To Ecr - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.4.4.8

Connecting Cables and the Line Network

Not for U.S. and Canada Connection cable for the expansion cabinet rack ECR (if
present)
To meet EMC requirements, the braided shields on the connection cable must be connected to
the housing on the HiPath 3500 or HiPath 3300 side and on the ECR side.
Attaching to the HiPath 3500 or HiPath 3300 side
A clip and a tooth lock washer are enclosed with the ECR mounting set. Use these and the
housing cover mounting screw to attach the braided shield to the HiPath 3500 or HiPath
3300 housing (as shown in Figure 4-111). The tooth lock washer must be mounted be-
tween the painted surface of the cover and the clip.
Figure 4-111
Attaching to the ECR side (see Page 9-9)
Line network
The connecting cords to the peripherals can be connected directly to the relevant MW8 jacks
on the front panel of the 19-inch housing.
4-196
HiPath 3500 and HiPath 3300 - Connection Cable to ECR
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Housing cover mounting screw
Clip
Tooth lock washer
Housing cover
P31003-H3560-S403-54-7620, 09/05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents