LED statuses and their meanings
Table 3-92
SLMO8 (Not for U.S.) and SLMO24 - LED Statuses
Red LED
Green
LED
Off
Off
On
Off
Flashing
Off
Off
On
Off
Flashing At least one subscriber line circuit is activat-
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Status
Board not receiving power or not plugged in
correctly.
Board is out of order.
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Loadware loading not successfully com-
pleted. Board is faulty.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000 Manager E.
Loadware is being loaded.
Board test completed successfully. Board is
OK (idle state).
ed.
boards.fm
Boards for HiPath 3000
Peripheral Boards
Action
Check plug contact on
board.
Replace board.
Replace board.
Check whether the board
was deactivated using Hi-
Path 3000 Manager E. If
not, replace board.