Siemens HiPath 5000 Service Manual page 350

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral Boards
LED statuses and their meanings
Table 3-114
TIEL - LED Statuses
LED Status
(on/off)
During Startup and Initialization
Flickering (50/50
ms)
Flashing (100/
100 ms)
On
Flashing (100/
100 ms)
Off
Flashing (500/
500 ms)
During Operation
On
Flashing in ring
cadence
Flickering (450/
50 ms)
Flashing (500/
500 ms)
Off
3-260
Meaning
Board test unsuccessful
Board not configured
Loading in progress
Code could not be loaded
Board loaded
Board loaded but not yet activated
Circuit seized
Circuit in ringing state
Dependability test (loopback test)
in progress
Circuit out of service (e.g. S1/x in
"on" position")
Circuit is idle, no seizure
Replace board.
Inspect visually, remove and re-insert
board if necessary.
Replace board if flashing continues.
Replace board.
Check whether the circuit was deacti-
vated with HiPath 3000 Manager E or
lockout switch.
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Action
P31003-H3560-S403-54-7620, 09/05