Checking Whether The Output Of A Power Supply Unit Is Sufficient - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

D.8

Checking Whether the Output of a Power Supply Unit is Sufficient

Apart from the secondary power requirements, the power output must also be checked to en-
sure that the maximum possible output of the system's power supply unit is sufficient. For this,
the power requirement on the 5-V output format and on the –48-V output format must be ex-
amined separately.
A separate calculation must be performed for every HiPath 3750 and HiPath 3700 system cab-
inet (in other words for every UPSM).
Caution
7
To guarantee smooth system operation, the nominal output of the power supply unit
at the 5-V output and at the –48-V output must be greater than the respective sec-
ondary power requirement.
Procedure
Proceed as follows to identify the secondary power requirement of a system:
1.
Determine secondary power requirement at the 5-V output
5 V power requirement of the boards/components used
=
secondary power requirement at the 5-V output
2.
Determine secondary power requirement at the –48-V output
–48 V power requirement of the boards/components used
+
power requirement of connected workpoint clients (analog and digital telephones),
key modules and adapters
=
secondary power requirement at the –48-V output
Using the specified values, check whether the total power requirement exceeds the maximum
possible output of the power supply unit at the 5-V output or at the –48-V output. If this is the
case, you have the following options:
HiPath 3800
The number of LUNA2 power supply units can be increased.
HiPath 3750 and HiPath 3700 with UPSM
For multiple cabinet systems, the distribution of boards on the system cabinets can be op-
timized. Please observe the configuration notes in Section 4.3.6.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Checking Whether the Output of a Power Supply Unit is Sufficient
Identifying System Power Requirements
power_calc.fm
D-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800

Table of Contents