Installing the ECGM tool and configuring the CAS protocol converter
This section contains information on installing the ECGM tool on the service PC and for config-
uring the CAS protocol converter on the
The ECGM tool supports the following actions:
Extender, database and software download
●
CAS protocol configuration
●
Database programming
●
Trace options
●
Procedure
Step
1.
Create directory c:\ecginst on the service PC.
2.
Set up the connection to the download server (for information on this, contact your
local ITSC) and copy the following files into the directory c:\ecginst:
e1v0xx.exe (for example, e140ah.exe)
●
Ee1v0yy.exe (for example, Ee140am.exe)
●
Ecgm_vzz.exe (for example Ecgm_4aa.exe)
●
Explanation of the variables:
v = software version
●
xx = country version of a file
●
yy = file version for channels
●
zz = file version for maintenance
●
3.
Run .exe files. This will extract the following files, for example:
Ecgm.cab (WinZip file)
●
Setup.lst (LST file)
●
Setup.exe (EXE file)
●
4brazil.iam (IAM file)
●
Ecg_edb4.ein (EIN file)
●
4brazil.eam (EAM file)
●
E140ah.sin (SIN file)
●
E140ah.pnm (PNM file)
●
X140pai.pnm (PNM file)
●
X130aq.pnm (PNM file)
●
4.
Execute Setup.exe file. This will create the directory ecgm and extract various
files.
5.
Copy vbrazil.iyy (for example, 4brazil.iam) to the directory ecgm.
6.
Run the file ecgm.exe.
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
TMCAS
board.
Activity
boards.fm
Boards for HiPath 3000
Peripheral Boards
3-293