Boards for HiPath 3000
Peripheral Boards
3.3.15

SLMA2 (for selected countries only)

Introduction
The SLMA2 (Subscriber Line Module Analog) board provides analog T/R interfaces for use in
HiPath 3800.
The external ring generator
voltages. RGMOD is plugged in on the backplane of the basic and/or expansion cabinet. The
ring voltage and ring frequency are set using jumpers.
A system cabinet can be fitted with a mix of SLMA,
>
MOD has no effect on SLMA and SLMA8, as these boards generate their own ring
voltage.
Front panel
Two LEDs indicating the board status:
LED (red)
LED (green)
Figure 3-79
SLMA2 (S30810-Q2246-X) (for selected countries only) - LED's on the Front
Panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
>
tion on mounting the shielding panel, see Section 4.2.5.2.
3-186
RGMOD
(S30122-K5929-X) is required for the generation of ring
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
SLMA8
and SLMA2 boards. RG-
P31003-H3560-S403-54-7620, 09/05