Siemens HiPath 5000 Service Manual page 537

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

If
Slot with
CABLUs for connection between backplane (SIVAPAC connector) and
SLMA
MDFU-E (jumper strip for 25 TW):
1
SLMA2
SLMO2
CABLU for connection between backplane (SIVAPAC connectors) and ex-
ternal patch panel S30807-K6143-X (SIVAPAC socket terminal strip):
Open-end cable (24 TW) for connection between backplane (SIVAPAC con-
nector) and external patch panel:
Slot with
A CAS cable is connected via an APPCU adapter (S30807-K5415-X).
1
PBXXX
1
for selected countries only
2
for U.S. only
Information on cable and connector assignment is provided in the board descriptions in
Chapter 3.
Closing the backplane of the system cabinets
After the cable has been connected, the backplane of the basic cabinet and that of
>
the expansion cabinet (if applicable) must be closed with the dummy panels provid-
ed (C39165-A7075-C44).
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E
slots 11-21 (see Figure 4-37)
C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-37)
S30267-Z333-A20: 2 m in length (refer to Figure 4-43)
S30267-Z333-A50: 5 m in length (refer to Figure 4-43)
S30267-Z196-A150: 15 m in length
S30267-Z196-A250: 25 m in length
S30267-Z196-A350: 35 m in length
S30267-Z196-A550: 55 m in length
S30267-Z196-A950: 95 m in length
Installing HiPath 3000
Installing HiPath 3800
Then
inst_h3.fm
4-59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 3000Hipath 3800