4.2.5.3

Mounting Connector Panels (if required)

The HiPath 3800 has various connection options for connecting the peripherals. If you intend
to use connector panels, mount the panels supplied as follows:
If
Connector panels
with RJ45 jacks
(see
Section 4.2.6.5)
For U.S. only:
Connector panels
with CHAMP jack
(see
Section 4.2.6.6)
4-40
Slot with
Attach a connector panel with 8 RJ45 jacks (S30807-
STMD3
Q6624-X) to the SIVAPAC connector on the back-
plane.
Slot with
Attach a connector panel with 24 RJ45 jacks (S30807-
SLCN
Q6622-X) to the SIVAPAC connector on the back-
SLMA
plane.
SLMA8
SLMO2
SLMO8
TM2LP
1
TMC16
2
TMDID
different or no as-
Use filler panels to cover the backplane sections of
signment
other boards and empty board slots.
Slot with
Attach a connector panel with CHAMP jacks (S30807-
SLMA
Q6626-X) to the SIVAPAC connector on the back-
SLMA8
plane.
SLMO2
SLMO8
STMD3
TM2LP
1
TMC16
2
TMDID
different or no as-
Use filler panels to cover the backplane sections of
signment
other boards and empty board slots.