boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.18

SLU8

Introduction
The SLU8 board for HiPath 3550 and HiPath 3350 (wall housing) with 8 digital subscriber line
interfaces allows up to 16 digital telephones to be connected in host-client operation (master-
slave operation).
Interfaces
U
ports
P0/E
1-4
U
ports
P0/E
5-8
Figure 3-82
SLU8 Interfaces (S30817-Q922-A301)
Caution
7
After deactivating the power supply, you must wait a short while before plugging the
SLU8 in or out. If you do not wait before doing so, the CBCC/CBCP may be dam-
aged.
Table 3-96
SLU8 Contact Assignments
Contact
1
2
3
4
5
6
7
8
3-212
1
X2
8
1
X3
8
X2 (U
ports 1-4)
Po/E
a 1
b 1
a 2
b 2
a 3
b 3
a 4
b 4
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
SLU8
50
To
CUP/
X1
CUC
2
X3 (U
ports 5-8)
P0/E
a 5
b 5
a 6
b 6
a 7
b 7
a 8
b 8
P31003-H3560-S403-54-7620, 09/05