start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3750 and HiPath 3700
5.3.6
Customer-Specific Programming
You can program the system using one of the following tools:
Assistant T (programming telephone, see Appendix A)
●
HiPath 3000 Manager E (PC tool)
●
Changes to the system (for example key programming) made using during an HiPath
>
3000 Manager E offline programming session will be lost when the database is load-
ed.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
5.3.7
Performing a System Check
Checking the telephones
The display must be checked on every telephone. The phone number, date and time are
●
normally shown in the display.
If a different text appears ("Gateway not found", for example), this means that there is an
error.
Correct the error by following the administration instructions for the relevant telephone.
Perform random terminal tests as described in Section 12.3.1.8 on all telephones.
●
Checking for proper system booting
Set up internal and external calls at random to check if the system is functioning properly.
●
5-18
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
P31003-H3560-S403-54-7620, 09/05