Table 12-7
HiPath 3000 Class B Error Messages
No.
14
Overload Code Receiver CR
15
Overload Code Sender CS
Error Class B-23 - Network
60
System hold no buffer available
Error Class B-26 - Presence
0
Unknown card type
1
Board out of order
2
Maximum number of peripheral boards
exceeded
3
Board type not compatible, slot is already
pre-assigned with a different board model
4
Board is activated
Error Class B-28 - Recovery
0
COSMOS error: Data transmission not
possible
Error Class B-29 - IOP
0
COSMOS error
20
Port table queue is empty
24
Board malfunction
25
Board reset was detected
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Meaning
Action
Recovery
Check if these errors oc-
cur repeatedly or only
sporadically. If the errors
an additional CR8N board
can be used for HiPath
3750 and HiPath 3700.
An upgrade to the next
highest system may be
necessary for all other
Hard restart
Notify appropriate service
Reload board
Reduce peripheral boards
to maximum number
Hard restart
Notify appropriate service
Hard restart
Notify appropriate service
Hard restart
Reload board
Reload board
service.fm
Service
Guided Maintenance
Action
Technician
occur repeatedly,
systems.
support
Replace board
Replace board
support
support