boards.fm
Boards for HiPath 3000
Peripheral Boards
LED statuses and their meanings
Table 3-47
IVML8 and IVML24 - LED Statuses
LED
LED
Yellow
Green
During Startup and Initialization
Off
Off
On
On
On
Off
Off
Flashing
Off
(500/
500 ms)
Off
On
On
Off
During Operation
Off
On
Off
Flashing
(500/
500 ms)
Flashing
Flashing
(500/
(500/
500 ms)
500 ms)
On
Off
3-118
Meaning
1 Boot procedure (lasts approx. 8 - 12 s)
2 LED test (lasts approx. 10 s)
3 Lockout switch state signaling by yellow
LED (lasts approx. 5 s):
blocked = On
free = Off
4 Hard disk test, start of the application (de-
pending on hard disk status, lasts approx.
3 - 8 minutes)
5a Standby mode after successful boot
5b Board locked or board error occurred
Idle (no call)
At least one active port (call)
Lockout switch activated during a call
Board locked or board error occurred
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Action
If necessary, check
whether the board was
deactivated using Hi-
Path 3000 Manager E or
lockout switch.
Check whether board
was deactivated using
HiPath 3000 Manager E
or lockout switch.
Check whether board
was deactivated using
HiPath 3000 Manager E
or lockout switch.