Siemens HiPath 5000 Service Manual page 325

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

LED statuses and their meanings
H300 LED (see Figure 3-94): Reference clock display (clock is generated if this feature was
configured using HiPath 3000 Manager E).
On: Reference clock for clock generator is created.
Off: No reference clock
LEDs H301 to H308 (see Figure 3-94)
Table 3-106
STMD8 - LED Statuses (H301 to H308)
LED Status
(on/off)
During Startup and Initialization
Flickering
(50/50 ms)
Flashing
(100/100 ms)
On
Flashing
(100/100 ms)
Off
Flashing
(500/500 ms)
During Operation
On
Flickering
(450/50 ms)
Flashing
(500/500 ms)
Off
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Meaning
Board test unsuccessful
Board not configured
Loading in progress
Code could not be loaded
Board loaded
Board loaded but not yet activated
ISDN layer 2 activated
Dependability test (loopback test)
in progress
Board is out of service (e.g. S300/x
"closed")
ISDN layer 2 not activated
Boards for HiPath 3000
Action
Replace board.
Inspect visually, remove and re-insert
board if necessary.
Replace board if flashing continues.
Replace board.
Check whether board was deactivat-
ed using HiPath 3000 Manager E or
lockout switch.
boards.fm
Peripheral Boards
3-235