Figure 3-108 E&M Interface Type 2 (Not For U.s) - Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

boards.fm
Boards for HiPath 3000
Peripheral Boards
E&M interface type 2 (not for U.S)
TIEL
- 48 V
E
1
4
2 3
5 6
CCT 1: S103
CCT 2: S203
CCT 3: S303
CCT 4: S403
Figure 3-108
E&M Interface Type 2 (Not for U.S)
3-258
E
SG
M
SB
1
2 3
S102
S202
S302
S402
Remote system//transmission-
equipment with TIEL
E
SG
M
SB
CCT 1: S103
CCT 2: S203
CCT 3: S303
CCT 4: S403
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
- 48 V
E
1
4
1
2 3
5 6
2 3
S102
S202
S302
S402
P31003-H3560-S403-54-7620, 09/05