Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Digital and analog trunks and subscriber lines from HiPath 3550 (wall housing)
The accessory pack does not contain enough ferrite sleeves for all trunks and sub-
>
scriber lines possible in a maximum system configuration. In this case, you will need
to order additional ferrite.
If
Trunk board or
Guide both standard cables from SU X8 and SU X9 (see Figure 4-100) to
subscriber line
the MDFU through two ferrite sleeves (C39022-Z7000-C7) each. The ferrite
modules in Hi-
should be placed as far inside the housing as possible.
Path 3750 for-
mat
Trunk or sub-
Guide the trunk and subscriber lines of all ports connected on a board
scriber line
through a ferrite sleeve twice, i.e. in a loop. The ferrite should be fixed in the
modules in
cable duct if possible. If the number of lines makes this impossible, the ferrite
"small" format
can be attached directly at the output of the cable duct.
4-182
Then
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
P31003-H3560-S403-54-7620, 09/05