4.4.4.2
Selecting the Installation Site
Selecting a site
The customer usually has a preferred installation site in mind, for example an existing 19-inch
cabinet.
Make sure that the customer's site meets the following guidelines:
To guarantee sufficient system ventilation, allow a minimum of 10 cm clearance around the
●
housing.
Do not expose the systems to direct sources of heat (for example sunlight and heaters).
●
Do not expose the systems to extremely dusty environments.
●
Avoid contact with chemicals.
●
Take every precaution to prevent the formation of condensation on the system during op-
●
eration. Systems covered with condensation must be dried before being used.
Observe the environmental conditions specified in Section 2.11.
●
You will find information on the design and dimensions in the following section:
HiPath 3500 Section 2.2.2.6
●
HiPath 3300 Section 2.2.2.7
●
4.4.4.2.1
For U.S. only: AC outlet
The AC connection must fulfill the requirements specified in Table 4-22.
Table 4-22
Electrical Connection Values (for U.S. only)
Nominal
Nominal voltage range
voltage
from
120 V AC/
110 V AC
60 Hz
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Nominal Frequency
to
from
130 V AC
47 Hz
Wall Outlet Configura-
Range
to
63 Hz
NEMA 5-15, 2-pin, 3-
wire, earth
inst_h3.fm
Installing HiPath 3000
tions
4-189