service.fm
Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
22
HiPath License Management: License
Failure Period was stopped. System in li-
censing default
Error Class B-20 - Call Processing
0
Error in pointer administration
1
Maximum number of stations achieved
2
RS232: Interface not present (DSR)
11
RS232: Interface ready (DSR)
13
All routes allocated
Error Class B-21 - Device Handler
0
No dial tone detected
1
Dial tone detected
7
Reference clock on
8
Reference clock off
11
Fan alarm (19'' housing for HiPath 3500/
HiPath 3300): Error
12
Fan alarm (19'' housing for HiPath 3500/
HiPath 3300): Error corrected
13
No response from temperature sensor in
the 19'' housing for HiPath 3500/HiPath
3300
12-54
Meaning
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
Action
Recovery
Hard restart
Notify appropriate service
Hard restart
Notify appropriate service
Use headset to check dial
If there is no dial tone, re-
Check to see if the fan has
broken down and/or if the
ventilation openings in the
housing are unblocked.
P31003-H3560-S403-54-7620, 09/05
Action
Technician
Check licensing
support
Reduce stations
Check interface
support
tone.
place board.
Replace CBRC