boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-68
EPSU2 - Explanation of Indicators and Ports
LED 1
LED 2
(DC output)
(AC input)
On
Off
On
Off
Ports
Battery fuse
AC port (input)
DC port (output)
EPSU2 technical specifications
Table 3-69
EPSU2 - Technical Specifications
Scope of delivery
AC power cable
3-166
On
DC output and AC input voltages are OK.
On
No DC voltage at output
(for example DC load short-circuited).
Off
No AC voltage at input
(power outage, circuit-breaker panel receiving battery power).
Off
No AC input voltage (power outage) and batteries are empty, or
the battery fuse is defective or was removed (for example by turn-
ing it to the left).
Melting fuse 5 x 20 mm, 2.5 A/slow-blowing
IEC 320/16 (grounding power cable/IEC)
Screw terminal connections for insulated lines (0.5 – 2.5 mm
56 V, 140 W
EPSU2 S30122-K7221-X1 = 2-wire power cable to UPSC-D,
pre-installed, soldered ends. Note polarity.
EPSU2 S30122-K7221-X2 = 2-wire power cable to UPSC-D,
with Phoenix terminal block.
S30122-K7221-X1
EPSU2 AC/DC converter
with four UPS batteries
loaded
Operating instructions
AC connecting cable (pro-
tective grounding plug,
IEC-320 socket)
DC cable to UPSC-D
(length = 2 m)
C39195-Z7001-C17 Euro angled
C39195-Z7001-C20 GBR angled
Description
Description
EPSU2
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
EPSU2
S30122-K7221-X2
EPSU2 AC/DC converter
without batteries
Operating instructions
AC connecting cable (pro-
tective grounding plug,
IEC-320 socket)
DC cable to UPSC-D
(length = 2 m)
P31003-H3560-S403-54-7620, 09/05